Force Characterization of Intracranial Endovascular Embolization

Author:

Lamano Jonathan B.12,Bushnell Grace G.1,Chen Hongyu1,Badrinathan Avanti1,Tecle Najib E. El12,Bendok Bernard R.234,Glucksberg Matthew R.1

Affiliation:

1. Department of Biomedical Engineering, Northwestern University, Evanston, Illinois

2. Department of Neurological Surgery, Northwestern University, Chicago, Illinois

3. Department of Otolaryngology, Northwestern University, Chicago, Illinois

4. Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois

Abstract

Abstract Background: Intraoperative rupture (IOR) is a rare, but potentially morbid complication of endovascular aneurysm coil embolization. Yet, IOR predictors have remained relatively uninvestigated in relation to coil design. Objective: To develop a novel in vitro aneurysm model to characterize forces exerted by coils of different design on the aneurysm during endovascular embolization that are hypothesized to contribute to IOR. Methods: A 3-mm saccular aneurysm model was developed with flat latex membrane at the dome apex. Membrane deflection was observed throughout simulated embolization and converted to force measurement. Simultaneous coil insertion and force measurement were accomplished with a compression strength-testing machine. Membrane and insertion forces across coil type, microcatheter tip placement, and insertion rate were evaluated. Results: Insertion force and force directly on the aneurysm wall exhibited a difference, with framing coils exerting greatest force, followed by filling and finishing coils. Regarding microcatheter placement, a similar graded response in membrane and insertion forces was observed with positioning in the top-third of the aneurysm generating the greatest force compared with central and bottom-third placement. Insertion rate was also a factor with the slowest rate (10 mm/min) exhibiting the greatest membrane force, followed by lower forces at 30 and 50 mm/min. A multiple linear regression model was created to assess the contributions of each factor toward aneurysm forces. Conclusion: Increased force on the aneurysm is associated with framing coil use, microcatheter placement proximal to aneurysm dome, and slow insertion rate. Further characterization remains necessary to reduce IOR risk, especially concerning the contributions of insertion rate.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Clinical Neurology,Surgery

Reference16 articles.

1. Predictors and outcomes of intraprocedural rupture in patients treated for ruptured intracranial aneurysms: the CARAT study;Elijovich;Stroke,2008

2. Prevention and management of intraprocedural rupture of intracranial aneurysm with detachable coils during embolization;Li;Neuroradiology,2006

3. Outcomes after aneurysm rupture during endovascular coil embolization;Tummala;Neurosurgery,2001

4. Endovascular coil embolization of very small intracranial aneurysms;Hwang;Neuroradiology,2011

5. Cerebral aneurysm perforations complicating therapy with Guglieme detachable coils: a meta-analysis;Cloft;AJNR Am J Neuroradiol,2002

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3