Use of Coils in Conjunction With the Pipeline Embolization Device for Treatment of Intracranial Aneurysms

Author:

Lin Ning12,Brouillard Adam M.12,Krishna Chandan12,Mokin Maxim12,Natarajan Sabareesh K.12,Sonig Ashish12,Snyder Kenneth V.12345,Levy Elad I.1245,Siddiqui Adnan H.12456

Affiliation:

1. Department of Neurosurgery, School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, New York

2. Department of Neurosurgery, Gates Vascular Institute/Kaleida Health, Buffalo, New York

3. Department of Neurology, School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, New York

4. Department of Radiology, School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, New York

5. Toshiba Stroke and Vascular Research Center, University at Buffalo, State University of New York, Buffalo, New York

6. Jacobs Institute, Buffalo, New York

Abstract

ABSTRACT BACKGROUND: Coiling in conjunction with Pipeline embolization device (PED) placement could provide immediate dome protection and an intraaneurysmal scaffold to prevent device prolapse for intracranial aneurysms with high rupture risk and complex anatomy. OBJECTIVE: To report results after treatment of aneurysms with PED with coils (PED+coils group) or without (PED-only group) at a single-institution. METHODS: In this case-controlled study, records of patients who underwent PED treatment between 2011 and 2013 were retrospectively reviewed. RESULTS: Twenty-nine patients were treated with PED+coils and 75 with PED-only. No statistically significant between-group differences were found in terms of age, sex, aneurysm location, medical comorbidities, and length of follow-up. Aneurysms treated by PED+coils were larger (16.3 mm vs 12.4 mm, P = .02) and more likely to be ruptured (20.7% vs 1.3%, P = .001) or dissecting (34.5% vs 9.3%, P = .002). PED deployment was successful in all cases. At the latest follow-up (mean, 7.8 months), complete aneurysm occlusion was achieved in a higher proportion of the PED+coils group (93.1% vs 74.7%, P = .03). Device foreshortening/migration occurred in 4 patients in the PED-only group and none in the PED+coils group. Fewer patients required retreatment in the PED+coils group (3.4% vs 16.0%, P = .71). Rates of neurological complications (10.3% PED+coils vs 8.0% PED-only, P = .7) and favorable outcome (modified Rankin Scale score = 0-2; 93.1% PED+coils vs 94.7% PED-only, P = .6) were similar. CONCLUSION: PED+coils may be a safe and effective treatment for aneurysms with high risk of rupture (or rerupture) and complex anatomy. Coiling in conjunction with PED placement provided a higher aneurysm occlusion rate and reduced the need for retreatment.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3