Affiliation:
1. Department of Neurosurgery, Virginia Commonwealth University Health System, Medical College of Virginia, Richmond, Virginia
Abstract
Abstract
BACKGROUND
The Pipeline Embolization Device (PED) is a treatment modality for wide-neck complex intracranial aneurysms. There have been recent reports for the use of PEDs in dissecting pseudoaneurysms of the cervical carotid arteries. The use of this flow diversion technology has emerged as a promising alternative; however, there are various risks and complications that one should be aware of.
OBJECTIVE
To report a rare postoperative complication, identified during follow-up, in a patient initially treated for an internal carotid artery dissection with multiple overlapping PEDs.
METHODS
A 53-year-old male with unremarkable history presented with acute Horner's syndrome, and imaging findings revealing internal carotid artery dissection and pseudoaneurysm with significant flow-limiting stenosis. He underwent treatment with a PED.
RESULTS
At 3 months post-operation, a cerebral angiogram demonstrated that one of his pipeline stents in the posterior cavernous segment had collapsed at its central portion. Flow was preserved around the outside of the collapsed device. We performed 4 rounds of balloon angioplasty with modest, but not complete, re-expansion of the stent. The patient has been doing well in the postoperative period with no complications.
CONCLUSION
The PED's role in the management of aneurysms and other intra- and extra-cranial vascular pathologies continues to expand, and new complications are bound to be discovered, similar to our case. As the use of these devices becomes routine and widespread, the frequency of these complications will increase. The management of unforeseen complications of PEDs, such as a collapsed stent, will need to be determined on an individual basis.