Implantation of Pipeline Flow-Diverting Stents Reduces Aneurysm Inflow Without Relevantly Affecting Static Intra-aneurysmal Pressure

Author:

Kerl Hans U.1,Boll Hanne1,Fiebig Teresa1,Figueiredo Giovanna1,Förster Alex1,Nölte Ingo S.1,Nonn Andrea2,Groden Christoph1,Brockmann Marc A.2

Affiliation:

1. University of Heidelberg, Medical Faculty Mannheim, Department of Neuroradiology, Mannheim, Germany

2. University Hospital of the RWTH Aachen, Department of Diagnostic and Interventional Neuroradiology, Aachen, Germany

Abstract

Abstract BACKGROUND: Flow-diverting stent (FDS) implantation is an endovascular treatment option for intracranial aneurysms. However, little is known about the hemodynamic effects. OBJECTIVE: To assess the effect of stent compression on FDS porosity, to evaluate the influence of single and overlapping implantation of FDS on intra-aneurysmal flow profiles, and to correlate stent porosity with changes in static mean intra-aneurysmal pressure. METHODS: Intra-aneurysmal time-density curves were recorded in a pulsatile in vitro flow model before and after implantation of FDSs (Pipeline Embolization Device; ev3) in 7 different types of aneurysm models. Reductions in the maximum contrast inflow and time to maximum intra-aneurysmal contrast were calculated. Micro--computed tomography was performed, and compression-related FDS porosity was measured. The influence of FDS placement on mean static intra-aneurysmal pressure was measured. RESULTS: FDS compression resulted in an almost linear reduction in stent porosity. Stent porosity (struts per 1 mm) correlated significantly with the reduction of aneurysm contrast inflow (R2 = 0.81, P < .001) and delay until maximum contrast (R2 = 0.34, P = .001). Circulating intra-aneurysmal high-velocity flow was terminated in all sidewall models after implantation of a single stent. Superimposition of 2 stents reduced maximum intra-aneurysmal contrast by 69.1 ± 3.1% (mean ± SD) in narrow-necked sidewall aneurysm models, whereas no substantial reduction in maximum intra-aneurysmal contrast was observed in wide-necked sidewall aneurysm models. Intra-aneurysmal mean static pressure did not correlate with FDS porosity or number of implanted stents. CONCLUSION: Implantation of FDS effectively reduces aneurysm inflow in a porosity-dependent way without relevantly affecting static mean intra-aneurysmal pressure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3