Correlation Among Anatomic Landmarks, Location of Subthalamic Deep Brain Stimulation Electrodes, Stimulation Parameters, and Side Effects During Programming Monopolar Review

Author:

Matias Caio M12,Mehanna Raja3,Cooper Scott E14,Amit Amit1,Lempka Scott F1,Silva Danilo15,Carlotti Carlos G2,Butler Robert S6,Machado Andre G15

Affiliation:

1. Center for Neurological Restoration, Cleveland Clinic Neurological Institute, Cleveland, Ohio

2. Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil

3. University of Texas Health Science Center, Houston, Texas

4. Department of Neurology, Cleveland Clinic Neurological Institute, Cleveland, Ohio

5. Department of Neurosurgery, Cleveland Clinic Neurological Institute, Cleveland, Ohio

6. Quantitative Health Sciences, Cleveland Clinic, Cleveland, Ohio

Abstract

Abstract BACKGROUND Clinical benefits of deep brain stimulation can be limited by the presence of side effects produced by current spread to adjacent structures. OBJECTIVE To identify a correlation between coordinates for each individual contact, neighboring structures, and pattern of side effects. METHODS Coordinates of the electrodes and anatomic landmarks were obtained with a stereotactic surgical planning software and were correlated with stimulation-related side effects by using univariate and multivariable analyses. RESULTS Monopolar stimulation elicited capsular side effects (CSEs) in 208 of 316 contacts (65.8%) and noncapsular side effects (NCSEs) in 223 of 316 contacts (70.6%). The occurrence of CSEs was correlated with contact number (P = .009) and with the “Z” (P = .03), whereas voltage threshold to CSEs exhibited correlation with the internal capsule angle (P = .035). The occurrence of NCSEs was correlated with contact number (P = .005), “X” (P = .03), “Y” (P = .004), and the distance to the red nucleus (P = .001 and P = .003). There was correlation between voltage threshold to NCSEs and the internal capsule angle (P = .006), electrode's coronal angle (P = .02), “X” (P = .001), “Y” (P < .001), “Z” (P < .001), and the distances to the internal capsule (P = .02) and to the red nucleus (P = .004 and P < .001). CONCLUSION A better understanding how patient anatomy, stimulation parameters, and lead location in relation to neighboring structures influence the occurrence of side effects can be useful to inform targeting strategies.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3