Magnetic Resonance Imaging Conditionally Safe Neurostimulation Leads

Author:

Coffey Robert J.1,Kalin Ron2,Olsen James M.2

Affiliation:

1. Research, Clinical, and Medical Safety, Medtronic Neuromodulation, Minneapolis, Minnesota

2. Research, Medtronic Neuromodulation, Minneapolis, Minnesota

Abstract

Abstract BACKGROUND: Magnetic resonance imaging (MRI) is preferred for imaging the central nervous system (CNS). An important hazard for neurostimulation patients is heating at the electrode interface induced, for example, by 64-MHz radiofrequency (RF) magnetic fields of a 1.5T scanner. OBJECTIVE: We performed studies to define the thermal dose (time and temperature) that would not cause symptomatic neurological injury. METHODS: Approaches included animal studies where leads with temperature probes were implanted in the brain or spine of sheep and exposed to RF-induced temperatures of 37°C to 49°C for 30 minutes. Histopathological examinations were performed 7 days after recovery. We also reviewed the threshold for RF lesions in the CNS, and for CNS injury from cancer hyperthermia. Cumulative equivalent minutes at 43°C was used to normalize the data to exposure times and temperatures expected during MRI. RESULTS: Deep brain and spinal RF heating up to 43°C for 30 minutes produced indistinguishable effects compared with 37°C controls. Exposures greater than 43°C for 30 minutes produced temperature-dependent, localized thermal damage. These results are consistent with limits on hyperthermia exposure to 41.8°C for 60 minutes in patients who have cancer and with the reversibility of low-temperature and short-duration trial heating during RF lesion procedures. CONCLUSION: A safe temperature for induced lead heating is 43°C for 30 minutes. MRI-related RF heating above 43°C or longer than 30 minutes may be associated with increased risk of clinically evident thermal damage to neural structures immediately surrounding implanted leads. The establishment of a thermal dose limit is a first step toward making specific neurostimulation systems conditionally safe during MRI procedures.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Reference37 articles.

1. The AAPM/RSNA physics tutorial for residents;Price;MR imaging safety considerations. Radiological Society of North America. Radiographics,1999

2. Magnetic resonance imaging and surgical clips;Barrafato;Can J Surg,1984

3. MR imaging in patients with metallic implants;Laakman;Radiology,1985

4. Magnetic field effects on surgical ligation clips;Brown;Magn Reson Imaging,1987

5. MR imaging in patients with intracranial aneurysm clips;Becker;AJNR Am J Neuroradiol,1988