BACKGROUND AND OBJECTIVES: Ventriculo-peritoneal shunt procedures can improve idiopathic normal pressure hydrocephalus (iNPH) symptoms. However, there are no automated methods that quantify the presurgery and postsurgery changes in the ventricular volume for computed tomography scans. Hence, the main goal of this research was to quantify longitudinal changes in the ventricular volume and its correlation with clinical improvement in iNPH symptoms. Furthermore, our objective was to develop an end-to-end graphical interface where surgeons can directly drag-drop a brain scan for quantified analysis. METHODS: A total of 15 patients with 47 longitudinal computed tomography scans were taken before and after shunt surgery. Postoperative scans were collected between 1 and 45 months. We use a UNet-based model to develop a fully automated metric. Center slices of the scan that are most representative (80%) of the ventricular volume of the brain are used. Clinical symptoms of gait, balance, cognition, and bladder continence are studied with respect to the proposed metric. RESULTS: Fifteen patients with iNPH demonstrate a decrease in ventricular volume (as shown by our metric) postsurgery and a concurrent clinical improvement in their iNPH symptomatology. The decrease in postoperative central ventricular volume varied between 6 cc and 33 cc (mean: 20, SD: 9) among patients who experienced improvements in gait, bladder continence, and cognition. Two patients who showed improvement in only one or two of these symptoms had <4 cc of cerebrospinal fluid drained. Our artificial intelligence–based metric and the graphical user interface facilitate this quantified analysis. CONCLUSION: Proposed metric quantifies changes in ventricular volume before and after shunt surgery for patients with iNPH, serving as an automated and effective radiographic marker for a functioning shunt in a patient with iNPH.

Funder

National Science Foundation

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference12 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3