Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography

Author:

González-Martínez Jorge12,Bulacio Juan1,Thompson Susan1,Gale John1,Smithason Saksith2,Najm Imad1,Bingaman William12

Affiliation:

1. Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio

2. Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio

Abstract

ABSTRACT BACKGROUND: Robot-assisted stereoelectroencephalography (SEEG) may represent a simplified, precise, and safe alternative to the more traditional SEEG techniques. OBJECTIVE: To report our clinical experience with robotic SEEG implantation and to define its utility in the management of patients with medically refractory epilepsy. METHODS: The prospective observational analyses included all patients with medically refractory focal epilepsy who underwent robot-assisted stereotactic placement of depth electrodes for extraoperative brain monitoring between November 2009 and May 2013. Technical nuances of the robotic implantation technique are presented, as well as an analysis of demographics, time of planning and procedure, seizure outcome, in vivo accuracy, and procedure-related complications. RESULTS: One hundred patients underwent 101 robot-assisted SEEG procedures. Their mean age was 33.2 years. In total, 1245 depth electrodes were implanted. On average, 12.5 electrodes were implanted per patient. The time of implantation planning was 30 minutes on average (range, 15-60 minutes). The average operative time was 130 minutes (range, 45-160 minutes). In vivo accuracy (calculated in 500 trajectories) demonstrated a median entry point error of 1.2 mm (interquartile range, 0.78-1.83 mm) and a median target point error of 1.7 mm (interquartile range, 1.20-2.30 mm). Of the group of patients who underwent resective surgery (68 patients), 45 (66.2%) gained seizure freedom status. Mean follow-up was 18 months. The total complication rate was 4%. CONCLUSION: The robotic SEEG technique and method were demonstrated to be safe, accurate, and efficient in anatomically defining the epileptogenic zone and subsequently promoting sustained seizure freedom status in patients with difficult-to-localize seizures.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Clinical Neurology,Surgery

Reference102 articles.

1. Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures;Cardinale;Neurosurgery,2013

2. Stereoelectroencephalography in the presurgical evaluation of children with drug-resistant focal epilepsy;Cossu;J Neurosurg,2005

3. Stereo-EEG in children;Cossu;Childs Nerv Syst,2006

4. Epilepsy surgery in children: results and predictors of outcome on seizures;Cossu;Epilepsia,2008

5. Stereoelectroencephalography in the “difficult to localize” refractory focal epilepsy: early experience from a North American epilepsy center;Gonzalez-Martinez;Epilepsia,2013

Cited by 261 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献