Monteris AXiiiS Stereotactic Miniframe for Intracranial Biopsy

Author:

Manjila Sunil1,Knudson Kathleen E1,Johnson Carleton1,Sloan Andrew E1

Affiliation:

1. Brain Tumor and Neuro-Oncology Center and Department of Neurosurgery, University Hospitals Case Medical Center, Seidman Cancer Center, Case Comprehensive Cancer Center, Cleveland, Ohio

Abstract

Abstract BACKGROUND Stereotactic biopsy is an important and minimally invasive technique used for a variety of indications in neurosurgery. Initially, this technique required a frame, but recently there have been a number of newer, less cumbersome approaches to biopsy including robotic arms, fixed arms, and, more recently, skull-mounted miniframes. Miniframes are attractive because they are disposable and low profile. However, the relatively limited degree of freedom offered by currently available devices necessitates a preplanned burr hole, which in turn limits flexibility and multiple trajectories. The AXiiiS device is a skull-mounted, magnetic resonance imaging–compatible miniframe that provides a similar degree of freedom with a frame while maintaining a low-profile, disposable platform. OBJECTIVE To assess the image-guided trajectory alignment accuracy using AXiiiS stereotactic miniframe biopsy of intracranial lesions. The accuracy of the AXiiiS device is compared with the Navigus Trajectory Guide as platforms. METHODS After approval by our institutional review board, medical records of 10 neurosurgical patients with intracranial pathologies were chosen for AXiiiS stereotactic miniframe biopsy, and histological correlation was obtained. RESULTS Ten reported cases demonstrate the precision and ease of using the AXiiiS stereotactic miniframe for biopsy of intracranial lesions in conjunction with preoperative magnetic resonance imaging. Multiple trajectories and angles have been used with precision and safety. CONCLUSION The AXiiiS stereotactic miniframe is a feasible, safe, and disposable platform for multitrajectory intracranial biopsies. Compared with existing platforms, this novel device provides a more stable base and wider limits of trajectory angles with comparable accuracy and precision.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Clinical Neurology,Surgery

Reference17 articles.

1. Assessment of image guided accuracy in a skull model: comparison of frameless stereotaxy techniques vs. frame-based localization;Quinones-Hinojosa;J Neurooncol,2006

2. Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique;Woodworth;J Neurosurg,2006

3. VarioGuide: a new frameless image-guided stereotactic system—accuracy study and clinical assessment;Ringel;Neurosurgery,2009

4. Failed stereotactic biopsy in a series of 518 cases;Soo;Stereotact Funct Neurosurg,1995

5. Management strategies after nondiagnostic results with frameless stereotactic needle biopsy: retrospective review of 28 patients;Air;Surg Neurol Int,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3