Biomechanics of Dynamic Rod Segments for Achieving Transitional Stiffness With Lumbosacral Fusion

Author:

Lazaro Bruno C.R.1,Reyes Phillip M.2,Newcomb Anna G.U.S.2,Yaqoobi Ali S.2,Brasiliense Leonardo B.C.2,Sonntag Volker K.H.3,Crawford Neil R.2

Affiliation:

1. Department of Neurosurgery, Hospital São José do Avaí, Itaperuna, RJ Brazil

2. Spinal Biomechanics Laboratory, Department of Neurosurgery Research

3. Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona

Abstract

Abstract BACKGROUND: Transitioning from rigid to flexible hardware at the distal rostral or caudal lumbar or lumbosacral level hypothetically maintains motion at the transition level and protects the transition level and intact adjacent levels from stresses caused by fusion. OBJECTIVE: To biomechanically compare transitional and rigid constructs with uninstrumented specimens in vitro. METHODS: Human cadaveric L2-S1 segments were tested (1) intact, (2) after L5-S1 rigid pedicle screw-rod fixation, (3) after L4-S1 rigid pedicle screw-rod fixation, and (4) after hybrid fixation rigidly spanning L5-S1 and dynamically spanning L4-L5. Pure moments (maximum 7.5 Nm) induced flexion, extension, lateral bending, and axial rotation while motion was recorded optoelectronically. Additionally, specimens were studied in flexion/extension with a 400-N compressive follower load. Strain gauges on laminae were used to extract facet loads. RESULTS: The range of motion at the transition segment (L4-L5) for the hybrid construct was significantly less than for the intact condition and significantly greater than for the rigid 2-level construct during lateral bending and axial rotation but not during flexion or extension. Sagittal axis of rotation at L4-L5 shifted significantly after rigid 2-level or hybrid fixation (P < .003) but shifted significantly farther posterior and rostral with rigid fixation (P < .02). Instrumentation altered L4-L5 facet load at more than the L3-L4 facet load. CONCLUSION: The effect of the dynamic rod segment on the kinematics of the transition level was less pronounced than that of a fully rigid construct in vitro with this particular rod system. This experimental model detected no biomechanical alterations at adjacent intact levels with hybrid or rigid systems.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370