Comprehensive Assessment of Drug Kinetics, Neurotoxicity, and Safety of Sirolimus-Eluting Intracranial Stents in Canine Basilar Artery

Author:

Sun Xuan12,Wu Xiaojin3,Yang Ming12,Deng Yiming12,Jia Baixue12,Zhang Xuelei4,Zhang Min3,Pi Chaoqiong3,Bureau Christophe5,Caligiuri Giuseppina6,Miao Zhongrong12

Affiliation:

1. Interventional Neuroradiology, Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China;

2. China National Clinical Research Center for Neurological Diseases, Beijing, China;

3. Sino Medical Sciences Technology Inc. (Sinomed), Tianjin, China;

4. Department of Cerebrovascular Disease, Beijing Anzhen Hospital, Capital Medical University, Beijing, China;

5. AlchiMedics S.A.S., Paris, France;

6. Department of Cardiology, Université Paris Cité, Laboratory for Vascular Translational Science, INSERM U1148, Bichat University Hospital, Paris, France

Abstract

BACKGROUND AND OBJECTIVES: Sirolimus-eluting stents (SESs) have shown promise in treating intracranial atherosclerosis but concerns about potential neurotoxicity due to prolonged drug release exist. The aim of this study was to comprehensively assess the safety of SES, with a focus on neurotoxicity. METHODS: Stents (1.50 × 7 or 12 mm) were implanted into the basilar arteries of 154 Labrador Retrievers (weighing >25 kg and aged older than 1 year) divided into 4 groups: baer-metal stent, polymer-coated stent, standard-dose SES (sirolimus dose: 71 μg), and high-dose SES group (sirolimus dose: 284 μg). Pharmacokinetic analysis was conducted using liquid chromatography-mass spectrometry on blood and tissue samples, and analysis of brain tissue was performed with 5 different special stains and immunohistochemistry protocols to assess axonal degeneration, vacuolization, astrocyte proliferation, microglial activation, or widespread neurodegeneration. RESULTS: In the standard-dose SES group, the stent released 10.56% of the drug on day 1 and 95.41% on day 28 postimplantation. In the high-dose SES group, corresponding figures were 40.20% on day 1 and 98.08% on day 28. Systemic drug concentration consistently remained below 1.5 ng/mL throughout the study. Arterial tissue concentration reached its peak at day 28 days in the standard-dose group and at 7 days in the high-dose group. Importantly, the brain and related tissue concentrations remained below 0.4 µg/g in both standard-dose and high-dose SES groups, peaking on day 21 in the standard-dose group and day 1 in the high-dose group. The detailed 180-day safety assessment revealed no adverse effects on the brain, even at high sirolimus doses in the SES group. CONCLUSION: This study provides robust evidence supporting the long-term pharmacokinetic safety of SESs in the context of intracranial interventions for high-grade intracranial atherosclerosis. The results adequately alleviate concerns related to neurotoxicity and substantiate the feasibility of using these stents as a therapeutic choice in neurosurgery.

Funder

Ministry of Science and Technology of China

Sino Medical Sciences Technology Inc.

National Natural Science Foundation of China

National Key R&D Program of China

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3