Abstract

ABSTRACT BACKGROUND: Subthalamic nucleus deep brain stimulation (STN-DBS) is an established treatment for Parkinson's disease. OBJECTIVE: To characterize an optimized magnetic resonance imaging (MRI) sequence (high-resolution 3-dimensional T2*-weighted angiography [HR 3-D SWAN]) for direct STN targeting. METHODS: Sequence distortions were measured using the Leksell stereotactic phantom. Eight consecutive candidates for STN-DBS underwent HR 3-D SWAN MRI for direct identification of the 16 STN. Two senior neurosurgeons independently determined the boundaries of STN on a semiquantitative scale (ranging from 1 [identification very easy] to 4 [identification very difficult]) and the anatomic target within the nucleus. The anatomic data were compared with electrophysiological recordings (48 microrecordings). We examined the anatomic location of the active contacts on MRI. RESULTS: The mean distortion error over the phantom was 0.16 mm. For the 16 STNs, identification of the upper, internal, anterior, and external edges was considered to be easy (scores of 1 or 2). The distinction between the substantia nigra and the STN was rated 1 or 2 for all but 6 nuclei. In the mediolateral axis, electrophysiological recordings covered perfectly anatomic data. In the craniocaudal axis, the mean differences between the electrophysiological data and the anatomic data were 0.8 mm and 0.19 mm for the “entry” and “exit” of the STN, respectively. All active contacts were located within the STN on MRI. CONCLUSION: HR 3-D SWAN allows easy visualization of the STN. Adapted to stereotactic requirement, the sequence simplifies direct targeting in STN-DBS surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3