Spatial Topographies of Unilateral Subthalamic Nucleus Deep Brain Stimulation Efficacy for Ipsilateral, Contralateral, Midline, and Total Parkinson Disease Motor Symptoms

Author:

Shenai Mahesh B1,Romeo Andrew2,Walker Harrison C3,Guthrie Stephanie3,Watts Ray L3,Guthrie Barton L2

Affiliation:

1. Department of Neuroscience, Inova Health System, Falls Church, Virginia

2. Department of Neurosurgery, University of Alabama at Birmingham, Birmingham, Alabama

3. Department of Neurology, University of Alabama at Birmingham, Birmingham, Alabama

Abstract

Abstract BACKGROUND Subthalamic nucleus (STN) deep brain stimulation is a successful intervention for medically refractory Parkinson disease, although its efficacy depends on optimal electrode placement. Even though the predominant effect is observed contralaterally, modest improvements in ipsilateral and midline symptoms are also observed. OBJECTIVE To elucidate the role of contact location of unilateral deep brain stimulation on contralateral, ipsilateral, and axial subscores of Parkinson disease motor symptoms. METHODS Eighty-six patients receiving first deep brain stimulation STN electrode placements were identified, yielding 73 patients with 3-month follow-up. Total preoperative and postoperative Unified Parkinson Disease Rating Scale Part III scores were obtained and divided into contralateral, ipsilateral, and midline subscores. Contact location was determined on immediate postoperative magnetic resonance imaging. A 3-dimensional ordinary “kriging” algorithm generated spatial interpolations for total, ipsilateral, contralateral, and midline symptom categories. Interpolative reconstructions were performed in the axial planes (z = −0.5, −1.0, −1.5, −3.5, −4.5, −6.0) and a sagittal plane (x = 12.0). Interpolation error and significance were quantified by use of a cross-validation technique and quantile-quantile analysis. RESULTS There was an overall reduction in Unified Parkinson Disease Rating Scale Part III symptoms: total = 37.0 ± 24.11% (P < .05), ipsilateral = 15.9 ± 51.8%, contralateral = 56.2 ± 26.8% (P < .05), and midline = 26.5 ± 34.7%. Kriging interpolation was performed and cross-validated with quantile-quantile analysis with high correlation (R2 > 0.92) and demonstrated regions of efficacy for each symptom category. Contralateral symptoms demonstrated broad regions of efficacy across the peri-STN area. The ipsilateral and midline regions of efficacy were constrained and located along the dorsal STN and caudal zona incerta. CONCLUSION We provide evidence for a unique functional topographic window in which contralateral, ipsilateral, and midline structures may achieve the best efficacy. Although there are overlapping regions, laterality demonstrates distinct topographies. Surgical optimization should target the intersection of optimal regions for these symptom categories.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Clinical Neurology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3