Abstract

BACKGROUND: Managing patients with hydrocephalus and cerebrospinal fluid (CSF) disorders requires repeated head imaging. In adults, it is typically computed tomography (CT) or less commonly magnetic resonance imaging (MRI). However, CT poses cumulative radiation risks and MRI is costly. Ultrasound is a radiation-free, relatively inexpensive, and optionally point-of-care alternative, but is prohibited by very limited windows through an intact skull. OBJECTIVE: To describe our initial experience with transcutaneous transcranial ultrasound through sonolucent burr hole covers in postoperative hydrocephalus and CSF disorder patients. METHODS: Using cohort study design, infection and revision rates were compared between patients who underwent sonolucent burr hole cover placement during new ventriculoperitoneal shunt placement and endoscopic third ventriculostomy over the 1-year study time period and controls from the period 1 year before. Postoperatively, trans-burr hole ultrasound was performed in the clinic, at bedside inpatient, and in the radiology suite to assess ventricular anatomy. RESULTS: Thirty-seven patients with sonolucent burr hole cover were compared with 57 historical control patients. There was no statistically significant difference in infection rates between the sonolucent burr hole cover group (1/37, 2.7%) and the control group (0/57, P = .394). Revision rates were 13.5% vs 15.8% (P = 1.000), but no revisions were related to the burr hole or cranial hardware. CONCLUSION: Trans-burr hole ultrasound is feasible for gross evaluation of ventricular caliber postoperatively in patients with sonolucent burr hole covers. There was no increase in infection rate or revision rate. This imaging technique may serve as an alternative to CT and MRI in the management of select patients with hydrocephalus and CSF disorders.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3