Safety, Accuracy, and Efficacy of Robot-Assisted Stereo Electroencephalography in Children of Different Ages

Author:

Lu Rongrong1,Wang Min1,Zhang Yi1,Li Hao1,Zhou Yuanfeng2,Wang Yi2,Zhao Rui34ORCID

Affiliation:

1. Department of Neurosurgery, Children's Hospital of Fudan University, National Children's Medical Center (Shanghai), Shanghai, People's Republic of China;

2. Department of Neurology, Children's Hospital of Fudan University, National Children's Medical Center (Shanghai), Shanghai, People's Republic of China;

3. Department of Neurosurgery, Children's Hospital of Shanghai, Shanghai, People's Republic of China;

4. Department of Neurosurgery, Hainan Women and Children's Medical Center, Haikou, People's Republic of China

Abstract

BACKGROUND AND OBJECTIVES: Aimed to investigate the safety, accuracy, and efficacy of stereo electroencephalography (SEEG) in children of various ages, with particular emphasis on those younger than 3 years. There is limited guidance regarding whether SEEG can conducted on very young children. METHODS: This retrospective study was conducted between July 2018 and August 2022. It involved 88 patients who underwent 99 robot-assisted SEEG procedures at our center. The patients were categorized into 3 groups based on their age at the time of the robot-assisted SEEG procedures: group 1 (3 years and younger, n = 28), group 2 (age 3-6 years, n = 27), and group 3 (older than 6 years, n = 44). Clinical data, SEEG demographics, complications, and seizure outcomes were analyzed. RESULTS: A total of 675 electrodes were implanted, with an average of 6.82 ± 3.47 (2.00-16.00) electrodes per patient (P = .052). The average target point error for the 675 electrodes was 1.93 ± 1.11 mm, and the average entry point error was 1.30 ± 0.97 mm (P = .536 and P = .549, respectively). The overall percentage of complications was 6.06% (P = .879). No severe or long-term neurologic impairment was observed. Of the total 99 procedures included in this study, 78 were admitted for epilepsy surgery for the first time, while 9 patients were treated twice and 1 patient was treated 3 times. There were 21 radiofrequency thermocoagulation and 78 second-stage resective procedures performed after SEEG. There was no statistically significant difference in Engel class I outcomes among the patients who underwent SEEG in the 3 age groups (P = .621). CONCLUSION: Robot-assisted SEEG were demonstrated to be safe, accurate, and efficient across different age groups of children. This technique is suitable for children younger than 3 years who have indications for SEEG placement.

Funder

Science and Technology Innovation Plan Of Shanghai Science and Technology Commission

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3