Standardizing Physical Activity Monitoring in Patients With Degenerative Lumbar Disorders

Author:

Maldaner Nicolai12ORCID,Tang Megan1,Fatemi Parastou1,Leung Chris1,Desai Atman1,Tomkins-Lane Christy13,Zygourakis Corinna1ORCID

Affiliation:

1. Department of Neurosurgery, Stanford University Hospital and Clinics, Stanford, California, USA;

2. Department of Neurosurgery, University Hospital Zurich & Clinical Neuroscience Center, University of Zurich, Zurich, Switzerland;

3. Department of Health & Physical Education, Mount Royal University, Calgary, Canada

Abstract

BACKGROUND AND OBJECTIVES: Degenerative thoracolumbar disorders (DTDs) typically cause pain and functional impairment. However, little is known regarding the DTD impact on patient's real-life physical activity. The objective of this study is to validate a wearable measure of physical activity monitoring in patients with DTD and to create gender- and sex-specific performance thresholds that are standardized to the mean of a control population. METHODS: A commercially available smartwatch (Apple Watch) was used to monitor preoperative physical activity in patients undergoing surgery for DTD. Mean preoperative physical activity 2 weeks before the scheduled surgery was expressed as raw step count. Standardized z-scores were referenced to age- and sex-specific values of a control population from a large public database. Step counts were assessed for convergent validity with established patient-reported outcome measures, and impairment in activity was stratified into performance groups based on z-score cutoff values. RESULTS: Sixty-five patients (62% female) with a mean (±SD) age of 63.8 (±12.8) years had a mean preoperative daily step count of 5556 (±3978). Physical activity showed significant correlation with patient-reported outcome measures, including Oswestry disability index (r = −0.26, 95% CI: −0.47-0.01), 36-Item Short Form Survey Physical Component Summary score (r = 0.30, 95% CI: 0.06-0.51), and Patient-Reported Outcomes Measurement Information System Physical Function (r = 0.49, 95% CI: 0.27-0.65). “No,” “Mild,” “moderate,” and “severe impairment” in activity performance were defined as corresponding z-scores of >0, 0 to −0.99, −1 to −1.99, and ≤−2, accounting for 22%, 34%, 40%, and 5% of the study population. Each one-step category increase in activity impairment resulted in increased subjective disability as measured by the Oswestry Disability Index, 36-Item Short Form Survey Physical Component Summary, and Patient-Reported Outcomes Measurement Information System Physical Function (all P-values <.05). CONCLUSION: We establish the first wearable objective measure of real-life physical activity for patients with DTD, with the first age- and sex-adjusted standard scores to enable clinicians and researchers to set treatment goals and directly compare activity levels between individual patients with DTD and normal controls.

Funder

Stryker

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370