Minimum Clinically Important Difference in Patients Undergoing Minimally Invasive Transforaminal Lumbar Interbody Fusion

Author:

Nie James W.,Hartman Timothy J.,MacGregor Keith R.,Oyetayo Omolabake O.,Zheng Eileen,Singh Kern

Abstract

BACKGROUND: Few studies have established the minimum clinically important difference (MCID) in patients undergoing minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for physical function and pain. OBJECTIVE: To establish MCID for physical function and pain patient-reported outcome measures (PROMs) for MIS-TLIF through anchor- and distribution-based methods using the Oswestry Disability Index (ODI) as the anchor. METHODS: Ninety-eight patients undergoing primary MIS-TLIF with preoperative and 1-year postoperative ODI scores were identified. MCID was calculated using anchor- and distribution-based methods. ODI responders were classified as patients who decreased by 1 disability classification. PROMs of Patient-Reported Outcome Measurement Information System-Physical Function (PROMIS-PF), 12-Item Short Form Physical Component Score (SF-12 PCS), Visual Analog Scale (VAS) back/leg, and ODI were collected preoperatively and 1-year postoperatively. Anchor-based methods were average change, minimum detectable change, change difference, receiver operating characteristic curve, and cross-sectional analysis. Distribution-based methods were standard error of measurement, receiver change index, effect size, and 0.5 ∗ ΔSD. RESULTS: Anchor-based methods ranged from 4.2 to 11.9 for PROMIS-PF, 6.0 to 15.8 for SF-12 PCS, 1.8 to 4.6 for VAS back, and 2.1 to 4.0 for VAS leg. The area under the curve for receiver operating characteristic analysis ranged from 0.66 to 0.81. Distribution-based methods ranged from 1.1 to 3.9 for PROMIS-PF, 1.6 to 10.4 for SF-12 PCS, 0.5 to 1.6 for VAS back, and 0.6 to 1.8 for VAS leg. CONCLUSION: Patients undergoing MIS-TLIF had a wide range of MCID values. The receiver operating characteristic curve was selected as the most clinically appropriate method. The corresponding MCID values were 4.2 for PROMIS-PF, 6.8 for SF-12 PCS, 1.8 for VAS back, and 2.4 for VAS leg.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3