Midpoint of C7 Lateral Mass Serves as an Accurate Reference Point for the Placement of T1 Pedicle Screws: An Anatomic Study

Author:

Kim Kevin T.1,Panagos Michael1,Hentschel Matthew1,Sharma Ashish1,Han Nathan1,Chryssikos Timothy2,Schwartzbauer Gary1,Crandall Kenneth M.1,Sansur Charles A.1

Affiliation:

1. Department of Neurosurgery, University of Maryland School of Maryland, Baltimore, Maryland, USA;

2. Department of Neurosurgery, University of California, San Francisco, California, USA

Abstract

BACKGROUND AND OBJECTIVES: Free-hand placement of T1 pedicle screws can often be challenging. A reliable free-hand technique for placement of T1 pedicle screws can overcome some of the difficulties associated with poor fluoroscopy in this region. The purpose of this study was to propose a novel anatomic landmark for accurate identification of the T1 entry point using the midpoint of the C7 lateral mass as a reference point. Our hypothesis is that the midpoint of the C7 lateral mass is within 1–2 mm of the center of the T1 pedicle. METHODS: Using 3-dimensional reconstruction software, the pedicle of T1 and the lateral mass of C7 were isolated to assess the location of the T1 pedicle relative to the C7 lateral mass. Specifically, the distance between the center of the T1 pedicle and the center of the C7 lateral mass was measured on 40 computed tomography scans. Furthermore, a clinical validation of this technique was performed by assessing the postoperative computed tomography scans of 53 patients undergoing cervicothoracic instrumentation. The Gertzbein and Robbins classification system was used to grade the accuracy of T1 pedicle screw placements in all patients using this technique. RESULTS: The average horizontal deviation + SD from centers of the T1 pedicle and the C7 lateral mass was 0.398 mm ± 0.953 mm. The T1 pedicle on average was slightly medial to the center of the C7 lateral mass. A total of 98.1% of T1 pedicle screws placed in vivo using the free-hand technique were of Grade A. CONCLUSION: In this article, we demonstrate that the center of the C7 lateral mass overlays the T1 pedicle and the optimal entry point is immediately below the midpoint of the C7 lateral mass. This approach provides a practical and accurate landmark in posterior cervicothoracic spine procedures that reduce the need for additional radiation exposure or increased operative time with image-guided techniques.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Reference11 articles.

1. Free hand pedicle screw placement in the thoracic spine: is it safe?;Kim;Spine.,2004

2. Thoracic pedicle screw placement: free-hand technique;Lenke;Neurol India.,2005

3. Clinical accuracy of three-dimensional fluoroscopy (IsoC-3D)-assisted upper thoracic pedicle screw insertion;Sugimoto;Acta Med Okayama.,2010

4. Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques;Gelalis;Eur Spine J.,2012

5. Novel free-hand T1 pedicle screw method: review of 44 consecutive cases;Rivkin;J Neurosci Rural Pract.,2014

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3