Feasibility of Robotic Transorbital Surgery

Author:

Lee Min Ho12ORCID,Xiao Limin13ORCID,Fernandez-Miranda Juan C.1

Affiliation:

1. Department of Neurosurgery, Stanford University School of Medicine, Palo Alto, California, USA;

2. Department of Neurosurgery, Uijeongbu St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea;

3. Department of Neurosurgery, The First Affiliated Hospital of Nanchang University, Nanchang, China

Abstract

BACKGROUND AND OBJECTIVES: The transorbital approach (TOA) facilitates access to pathologies lateral to the optic nerve, a region that is difficult to access with an endonasal approach. In this study, we sought to investigate the feasibility of robotic-assisted surgery in lateral TOA. METHODS: Six colored-silicon-injected human postmortem heads were prepared for dissection. The DaVinci Xi model was used with a 0-degree camera, 8 mm in diameter. A black diamond microforceps with an 8-mm diameter and 10-mm jaw length was used. The entry point of V1 (superior orbital fissure), V3 (foramen ovale), and posterior root of the trigeminal ganglion were chosen as the surgical targets. The length from the entry opening to each target point was measured. The angles formed between pairs of target points were measured to obtain the horizontal angle (root of the trigeminal ganglion—entry—V1) and the vertical angle (root of the trigeminal ganglion—entry—V3). RESULTS: Dissection was performed on 12 sides (6 specimens). The median distance from the entry point was 55 mm (range 50-58 mm) to the entry point of V1 (superior orbital fissure), 65 mm (range 57-70 mm) to the entry point of V3 (foramen ovale), and 76 mm (range 70-87 mm) to the root of the trigeminal ganglion. Meanwhile, the median of surgical angle between the entry point and the target was 19.1° (range 11.8-30.4°) on the horizontal angle and 16.5° (range 6.2-21.6°) on the vertical angle. CONCLUSION: This study found that application of lateral TOA in robotic-assisted surgery is premature because of the large size of the tool. However, although the entrance in lateral TOA is narrow, the internal surgical space is wide; this offers potential for design of appropriate surgical tools to allow increase tool usage.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference31 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3