Dynamic Mixed-Reality Patient-Specific Aneurysm Clipping Simulation for Two Cases—A Feasibility Study

Author:

Joseph Fredrick J.1ORCID,Cuba Miguel1,Murek Michael2,Raabe Andreas2,Bervini David2ORCID

Affiliation:

1. Image Guided Therapy, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland;

2. Department of Neurosurgery, Inselspital Bern University Hospital and University of Bern, Bern, Switzerland

Abstract

BACKGROUND AND OBJECTIVE: Intracranial aneurysm (IA) clipping is a complex neurosurgical procedure which demands advanced technology to minimize risks and maximize patient outcomes. This study aims to evaluate the feasibility of training patient-specific microsurgical clipping procedures using a mixed-reality physical neurosurgical simulator for unruptured IA. METHODS: Two board-certified neurosurgeons were asked to simulate surgery in 2 patient-specific left-side unruptured middle cerebral artery-bifurcation IA models. The study was conducted in the operation theater under realistic conditions using a mixed-reality physical neurosurgical simulator. Time, procedural, and outcome-related information was collected. The participating neurosurgeons were encouraged to attempt all possible clipping strategies, even those deemed suboptimal, reporting the outcome of each strategy. Finally, to evaluate the feasibility and added value of integrating indocyanine green fluorescence angiography (ICG-FA) with the simulator, the ICG-FA videos for each clipping strategy were analyzed and compared with the reported clipping outcomes. RESULTS: Between 4 and 8, different clipping strategies were applied per aneurysm model; the number of strategies was higher in Patient Model 1 (6.5 ± 1.5) (more complex aneurysm) than in Patient Model 2 (5.0 ± 1.0). The clipping strategies differed between surgeons. At most, 53.5 minutes were necessary to complete each training session, but more than double the time was spent on the more complex aneurysm. Up to 53.8% (Patient Model 1) and 50% (Patient Model 2) of the attempted strategies were discarded by the neurosurgeons during the simulation. Evaluation of aneurysm occlusion through ICG-FA was specific, although sensitivity was poor. CONCLUSION: The present mixed-reality patient-specific simulator allows testing, anticipating, and discarding different aneurysm microsurgical clipping strategies regardless of the pathology complexity. Specific limitations should be considered regarding ICG-FA aneurysm inspection after clipping.

Funder

Innosuisse - Schweizerische Agentur für Innovationsförderung

Schweizerische Herzstiftung

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3