Endoscopic Placement of Intracystic Catheters: A Technical Note

Author:

Peto Ivo12,Reynolds Rebecca A.2,Hartnett-Wright Sara12,Rodriguez Luis F.2,Jallo George I.2,Smyth Matthew D.2,Akbari S. Hassan A.2

Affiliation:

1. Department of Neurosurgery and Brain Repair, Morsani College of Medicine, University of South Florida, Tampa, Florida, USA;

2. Department of Pediatric Neurosurgery, Institute for Brain Protection Sciences, All Children's Hospital, Johns Hopkins University, St. Petersburg, Florida, USA

Abstract

BACKGROUND: Intraventricular neuroendoscopic surgery for tumor resection, biopsy, or cyst fenestration frequently requires precise placement of an intraventricular or intracystic catheter. Placement under direct visualization is not feasible because of small bore of working channel of the standard small ventriculoscope. Various techniques have been reported using a separate transcortical trajectory, endoluminal endoscope, or endovascular guide wire. OBJECTIVE: To describe a technique allowing precise placement of intraventricular/intracystic catheter using a small bore working ventriculoscope, without need for additional equipment. METHODS: Description of the technique including intraoperative photographs, video, and illustrative cases are provided. RESULTS: The peel-away sheath is peeled off approximately 1 to 2 cm to allow for the shaft of the endoscope to pass past its tip. Ventricular access is gained using the peel-away sheath. After the stylet is removed, the peel-away sheath is not peeled further or stapled to the skin. The endoscope is introduced into the ventricle through the peel-away sheath. After the required intraventricular work is performed, the endoscope is maneuvered into the location of the desired catheter position. The peel-away sheath is slowly advanced over the stationary endoscope past its tip. While the peel-away sheath is being held in place, the endoscope is removed. After the catheter has been introduced into the peel-away sheath to a premeasured depth, the peel-away sheath is peeled and removed. The catheter is then connected to collection system, reservoir or shunt system. CONCLUSION: The current technique allows for the precise placement of intraventricular/intracystic catheters without the need for additional equipment or a separate transcortical trajectory.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3