The First Clinical and Functional Results of Myopia Correction Using a Solid-State Laser Unit

Author:

Maychuk N. V.1ORCID,Tikhov A. V.2,Takhchidi Kh. P.3,Sarkhadov N. Sh.4,Malyshev I. S.5ORCID

Affiliation:

1. YourMed Clinics; Voronezh State Medical University

2. Laser Eye Microsurgery Clinic

3. Pirogov Russian National Research Medical University

4. YourMed Clinics

5. YourMed Clinics; Pirogov Russian National Research Medical University

Abstract

Relevance. Modern keratorefractive surgery (CRS) is a high-tech field of ophthalmology aimed at solving various problems of correcting a wide range of ametropias. Increasing the security of the RFI is one of the priority areas Purpose. To analyze the clinical and functional results of the use of the “Olimp™-2000” solid-state laser system during CRS using the method of superficial and sublamellar laser keratoablation and formulate recommendations for the therapeutic management of patients. Materials and methods. 53 patients (106 eyes) were examined, the average age was 28.5 ± 2.4 years. The inclusion criterion was moderate myopia and the absence of contraindications to CRC. If sufficient, taking into account safety criteria, CRS was performed by sublamellar keratoablation, if insufficient, superficial keratoablation was performed. In both cases, ablation was performed using a domestic solid-state laser machine. The observation period was 3 months. Pharmacological support in all cases was standard, adopted for the management of patients in FCMMG “YourMed”. Results. An analysis of the clinical and functional results of CRS using a solid-state laser device showed full compliance with the criteria set by the Food and Drug Administration (FDA). The accuracy of hitting the target refraction in the range of ± 0.5 diopters was 99.2 %; in 3 months of observation, no regression of the obtained refractive result was observed in any case. There was no loss of lines in any case, the BCVA after the operation corresponded to or exceeded by 1–2 lines the BCVA before the operation. When performing superficial keratoablation, in two cases, the loss of line 1 of the NCVA was noted due to the development of early subepithelial fibroplasia, which required correction of the pharmacological support. Conclusion. The analysis of the clinical and functional results of the correction of moderate myopia using the “Olimp™-2000” solid-state laser device showed high efficiency in terms of efficiency, safety, and predictability, despite little experience in using solid-state ablation in clinical practice. The use of Floas Mono® did not cause side effects in all cases and contributed to the smooth course of the early postoperative period. Thus, this drug is effective in the postoperative period and can be recommended for use in patients after CRC. The generation of ultraviolet radiation by modern solid-state devices for the purpose of correcting ametropia is a promising direction in CRS.

Publisher

PE Polunina Elizareta Gennadievna

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3