Calculation of IOL Optical Power Using OKULIX Ray-Tracing Software in Real Clinical Practice

Author:

Pershin K. B.1,Pashinova N. F.1,Tsygankov A. Yu.2,Kosova I. V.2

Affiliation:

1. “Eximer” Eye Center; Academy of postgraduate education of The Federal Medical‑Biological Agency

2. “Eximer” Eye Center

Abstract

Purpose. Comparative analysis of the accuracy of IOL optical power calculation using different biometric devices.Patients and methods. The study included 30 patients (30 eyes) after monolateral implantation of different monofocal and multifocal IOL models with a mean follow-up of 3.0 ± 0.2 (3–4) months. The mean age was 63.5 ± 6.5 (48–84) years. In all cases, IOL implantation was preceded by cataract phacoemulsification or refractive lensectomy. For all patients, IOL optic power, axial length and keratometry data were obtained using IOLMaster 500, Pentacam HR, and Pentacam AXL+OKULIX devices. Clareon, IQ Vivity, Hoya 250/251, and XY1-SP Vivinex IOLs were implanted.Results. The mean optical power for all implanted IOLs was +21.38 ± 3.50 D, range of values was +10.0 to +29.0 D. The average values of axial eye length were 23.50 ± 0.90 mm (21.25 to 25.19 mm). The target refractive IOLs optic power calculated with the three biometric systems did not differ significantly and was -0.464 ± 0.120 D, -0.502 ± 0.140 D, and -0.400 ± 0.110 D for IOLMaster, Pentacam, and Pentacam+OKULIX, respectively (p > 0.05). The Pentacam HR and Pentacam AXL+OKULIX had slightly lower MAE values; however, no significant differences were found in calculating IOL optical power for the three devices used (p > 0.05). When comparing the devices under study, significant differences were found for the rate of refractive power within ±0.5 D when using the IOLMaster on the one hand and OKULIX on the other (p < 0.05). The refractive error rate of ±1.0 D using the biometric devices did not differ significantly (p > 0.05).Conclusion. This paper presents the first Russian experience of using OKULIX ray-tracing software in clinical practice to increase the accuracy of optical power calculation of various IOL models. The advantage of Pentacam AXL+OKULIX over the IOLMaster 500 biometer in achieving a target refraction of ±0.5 D is shown.

Publisher

PE Polunina Elizareta Gennadievna

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3