Studying the Interaction of Viteral Substitutes with the Surface of Acrylic Intraocular Lenses

Author:

Plakhotniy M. A.1ORCID,Shichkova A. G.2,Kuznetsova O. S.2,Tereschenko A. V.3ORCID,Trifanenkova I. G.3ORCID,Yudina N. N.1ORCID,Shilov N. M.1ORCID

Affiliation:

1. Kaluga branch of the S. Fyodorov Eye Microsurgery Federal State Institution

2. Reper-NN

3. Kaluga branch of the S. Fyodorov Eye Microsurgery Federal State Institution; Kaluga state university named after K.E. Tsiolkovski

Abstract

Purpose of the study: In vitro to study the degree of adhesion of vitreous substitutes, such as silicone oil of various viscosities and perfluorodecalin (PFOS), to hydrophobic acrylic polymer IOLs and evaluate the interaction of vitreous substitutes with the model MIOL-Soft-23 in the clinic. Material and methods. IOLs of the model MIOL-Soft-23 were taken for the experiment. MIOL-Soft-23 are included in the RPR-20 set. IOL of the model MIOL-Soft-23 is made by photopolymerization from a biocompatible spatially cross-linked hydrophobic acrylic polymer based on oligomers and monomers of the methacrylic series with filters in the ultraviolet region of the spectrum from 19 to 23 D. For the experiment, silicone oils of different viscosities were taken: RS-OIL 2000 (Alchimia), SIL-5000-S (DORC), Oxane 5700 (Bausch & Lomb), PFOS (perfluorodecalin) Dk-line (Bausch & Lomb). Also, saline sodium chloride 0.9 % (Solofarm) was used. Results. Revealed a decrease in the degree of silicone adhesion to the surface of acrylic hydrophobic IOLs as the temperature rises, not less than 1.5 %. The absence of dependence of the degree of adhesion on the degree of viscosity of silicone oil was confirmed, which corresponds to the literature data. For the first time, the average percentage of adhesion of perfluorodecalin to the IOL surface data were obtained, in particular, the MIOL-Soft-23 model. The range of values ranged from 0.7 to 7.2 %. The average coverage percentage is 1.9 ± 1.3 % (exposure at 37 ± 1 °C for up to 14 days) and 3.4 ± 1.5 % (exposure at room temperature for up to 14 days). This confirms the need for careful intraoperative monitoring of the completeness of removal of PFOS droplets from the IOL surface. Conclusion. The presence of the risk of adhesion of residual drops of silicone oil and PFOS to the surface of the IOL necessitates careful intraoperative control of the completeness of the removal of vitreous body substitutes, as well as further search for the best ways to eliminate this complication. The conducted complex of studies makes it possible to recommend the use of IOL model MIOL-Soft-23 in complicated cases of vitreal surgery.

Publisher

PE Polunina Elizareta Gennadievna

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3