The thermal conductivity of gas mixtures

Author:

Abstract

The action of the katharometer as an instrument for gas analysis depends essentially upon the thermal conductivity of the gas mixture examined. One method of calibration for a given pair of gases is to make a number of mixtures of known composition by volume, and to obtain from them a curve showing how the deflection θ of the galvanometer in the bridge circuit of the instrument depends upon the composition of the mixture which surrounds one of the fine platinum helices. By reference to this curve, any other mixture of the two gases can be analysed when its deflection is known. A typical calibration curve is shown in fig. 1, which is for mixtures of helium and argon. The direction of the galvanometer deflection depends on whether the gas is a better or worse conductor than air. A useful convention is to regard the deflection for gases which are better conductors than air as positive. Daynes has examined the nature of the heat losses in the katharometer cell, which are due to ( a ) radiation, ( b ) convection, ( c ) conduction by the gas, ( d ) cooling of the platinum helix by metallic conduction along the copper lead. Even at the highest temperature used in the katharometer, the effect of ( a ) is very small, and will not be influenced directly by the nature of the gas surrounding the wire. Experiments have shown that the effect of ( b ) is also small. The effect of ( c ) on the temperature of the helix is large, and will depend upon the nature of the gas. The effect of ( d ) is also considerable, and will depend upon the temperature of the helix. This effect will consequently vary with the nature of the gas under examination, but the magnitude of the effect in the steady state which is reached depends upon the effect of ( c ) (the small effects of convection and radiation will similarly depend upon the effect of ( c )). Thus in practice, the thermal conductivity of the gas controls the temperature of the helix, and the instrument will give the same reading for all gases or mixtures having the same thermal conductivity. Owing to the complicated design of the katharometer cell, it is not possible to make a simple calculation of the heat loss due solely to the conductivity of the gas, or to devise a method of converting katharometer readings directly into thermal conductivities. It should be noticed also that the calibration curves for different instruments are not all of quite the same form, owing to small differences in the winding of the helix, or of its position in the cell.

Publisher

The Royal Society

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3