The spark-spectra of indium and gallium in the extreme ultra-violet region

Author:

Abstract

The spark-spectrum of indium in the ultra-violet has been especially studied by Saunders, that of gallium by Saunders and Klein. By the use of a one-metre concave grating, mounted in a brass tube which could be exhausted, Saunders was able to extend the indium spark-spectrum as far below into the ultra-violet as λ = 1699 A. U. The line of shortest wave-length as yet noted in the gallium spark-spectrum—namely, λ = 2176 A. U.—was measured by Klein with a large quartz spectrograph whose mounting was of the Littrow type. With the object in view of making a complete and comprehensive examination of the spark-spectral lines of the above elements, that should extend right through the extreme ultra-violet and the quartz regions, the following investigations were undertaken. A.— Experiments in the Quartz Region . 1. Description of Apparatus .—For studying the spectra in the quartz region a spark chamber, diagrammatically shown in the figure, was employed. The spark chamber proper was a pyrex bulb about 7 inches in diameter. The terminals were of gallium and aluminium in the one experiment, and indium and aluminium in the other. Gallium has a very low melting point (30·2° C.). It was therefore placed in a tiny quartz cup, which, supported by a long aluminium rod, formed the lower terminal for the discharge. A piece of tungsten wire led from the aluminium support through the stem of the cup to the gallium. The upper electrode was of aluminium filed down to a point. Pieces of pressure tubing, 2 inches in length, lined with soft wax, fitted over the terminal supports and the tube elongations from the spark chamber. These formed gas-tight moveable joints, and served for the purpose of adjusting the spaek gap. The gap ranged from 2 to 3 mm. in width. The quartz window, through which the light passed into the spectrograph, was fastened to the spark chamber with sealing wax. One stop-cock led to the exhaust pumps, the other to the system of drying tubes. The spark was produced by a primary current of 110 volts ranging from 4 to 6 amperes. A Hilger Quartz-Prism Spectrograph, Type A, was used. All photographs were taken on Schumann plates.

Publisher

The Royal Society

Subject

General Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3