In the Second Part of these researches we have given the results of our experiments on the difference between the temperatures of an elastic fluid on the high- and low-pressure sides of a porous plug through which it was transmitted. The gases employed were atmospheric air and carbonic acid. With the former, 0°·0176 of cooling effect was observed for each pound per square inch of difference of pressure, the temperature on the high-pressure side being 17°·25. With the latter gas, 0°·0833 of cooling effect was produced per lb. of difference of pressure, the temperature on the high-pressure side being 12°·844. It was also shown that in each of the above gases the difference of the temperatures on the opposite sides of the porous plug is sensibly proportional to the difference of the pressures.