1. School of Engineering, The University of Edinburgh, Edinburgh EH9 3DW, UK,
2. School of Engineering, University of Manchester, Manchester M13 9PL, UK
Abstract
Commonly deployed measurement systems for water waves are intrusive and measure a limited number of parameters. This results in difficulties in inferring detailed sea state information while additionally subjecting the system to environmental loading. Optical techniques offer a non-intrusive alternative, yet documented systems suffer a range of problems related to usability and performance. Here, we present experimental data obtained from a 256 × 256 Single Photon Avalanche Diode (SPAD) detector array used to measure water waves in a laboratory facility. 12 regular wave conditions are used to assess performance. Picosecond resolution time-of-flight measurements are obtained, without the use of dye, over an area of the water surface and processed to provide surface elevation data. The SPAD detector array is installed 0.487 m above the water surface and synchronized with a pulsed laser source with a wavelength of 532 nm and mean power <1 mW. Through analysis of the experimental results, and with the aid of an optical model, we demonstrate good performance up to a limiting steepness value,
ka
, of 0.11. Through this preliminary proof-of-concept study, we highlight the capability for SPAD-based systems to measure water waves within a given field-of-view simultaneously, while raising potential solutions for improving performance.