Affiliation:
1. NDE Group, Department of Mechanical Engineering, Imperial College, London SW7 2AZ, UK
2. Guided Ultrasonics Ltd., Brentford TW8 8HQ, UK
Abstract
Quantifying corrosion damage is vital for the petrochemical industry, and guided wave tomography can provide thickness maps of such regions by transmitting guided waves through these areas and capturing the scattering information using arrays. The dispersive nature of the guided waves enables a reconstruction of wave velocity to be converted into thickness. However, existing approaches have been shown to be limited in in-plane resolution, significantly short of that required to accurately image a defect target of three times the wall thickness (i.e. 3 T) in each in-plane direction. This is largely due to the long wavelengths of the fundamental modes commonly used, being around 4 T for both A0 and S0 at the typical operation points. In this work, the suitability of the first-order shear-horizontal guided wave mode, SH1, has been investigated to improve the resolution limit. The wavelength at the desired operating point is significantly shorter, enabling an improvement in resolution of around 2.4 times. This is first verified by realistic finite-element simulations and then validated by experimental results, confirming the improved resolution limit can now allow defects of maximum extent 3T-by-3T to be reliably detected and sized, i.e. a long-pursued goal of guided wave tomography has been achieved.
Funder
Engineering and Physical Sciences Research Council
Subject
General Physics and Astronomy,General Engineering,General Mathematics
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献