Rotational analysis of the first negative band spectrum of oxygen. II

Author:

Abstract

In a previous paper (Nevin 1938)*, the author has given an analysis of the (0, 1) λ 6438, (0, 0) λ 6026, and (1, 0) λ 5632 bands of the first negative band spectrum of oxygen and has shown that the system is due to a transition 4 - g 4 Π u . The present paper contains an analysis of the (0, 2) λ 6856 and (2, 0) λ 5295 bands. Using the method described in (I) to excite the spectrum, a discharge through helium containing a small amount of oxygen, the plates of the band λ 6856 taken in the second order of the grating could be measured only as far as λ 6720 on account of the large number of ghosts and the blackening produced below this point by the enormously over-exposed helium line λ 6678. To photograph the remainder of the band it was necessary to use a hollow cathode discharge through commercial oxygen as described by Frerichs (1926). This source is considerably less intense than the discharge through helium the exposures with which, in the case of the present band, were between 12 and 18 hr. with Ilford Astra III plates. To reduce the exposures to a reasonable time a cylindrical lens made by Hilger, 15 cm. long and 5 cm. wide with a focal length of 30 cm., was mounted at right angles to the axis of the spectrograph between the grating and the plate as described by Oldenberg (1932). The lens was mounted so that its axis could be adjusted exactly perpendicular to the slit and the grating rulings, a point of the highest importance if the definition is not to be impaired. As far as could be judged there was no loss of resolving power over the length of plate covered by the lens. Satisfactory exposures of a range of 180A were obtained in about 6 hr. with the hollow cathode discharge taking a current of 0.8 amp. The plates were measured with respect to third order iron standards. The λ 5295 band had already been photographed in the second order at the same time as the bands analysed in (I). However, to complete the analysis it was found necessary to take a third order plate, and to save time the arrangement described above was used, the entire band being obtained on a single plate with an exposure of 5 hr. The resolving power attained on this plate with sharp lines was about 200,000. The theoretical resolving power of the grating in this order is 250,000, so the reduction caused by the lens must have been very small. * Referred to as (I) throughout this paper.

Publisher

The Royal Society

Subject

Pharmacology (medical)

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3