Affiliation:
1. College of Architecture and Environment, Sichuan University, Chengdu 610065, People's Republic of China
Abstract
The electro-Fenton (EF) process was applied to treat mother liquor of gas field wastewater (ML-GFW). The Fe-Fe electrodes were used and H
2
O
2
was added to the EF system. Effect of initial pH on chemical oxygen demand (COD) removal efficiency, specific electrical energy consumption (SEEC), specific electrode plate consumption (SEPC) and organic matter removal mechanism was investigated. The results showed that COD removal efficiency reached the maximum (71.9%) at initial pH of 3 after reaction for 3 h. Besides, considering with the SEEC and SEPC, pH of 3 was also the best choice, at which SEEC was 4.7 kW h kg
COD
−1
, SEPC was 0.82 kgFe kg
COD
−1
. Organic matter removal was achieved by two ways: oxidation and flocculation, and oxidation played a major role. With the analysis of GC-MS, the possible degradation pathways of the representative contaminants in the ML-GFW were given.
Funder
International Scientific and Technological Innovation and Cooperation Project of Sichuan
Cited by
17 articles.