Abstract
The paper considers the steady-state harmonic response of an elastic fluid-loaded membrane supported by irregularly spaced ribs. Under the assumption of subsonic wave coupling, the solution is given exactly for any configuration as a product of 2 x 2 transfer matrices. It is well known that the response of a periodically ribbed membrane exhibits a pass/stop band structure. Although this structure is destroyed in the irregular case, we find that two distinct régimes remain: smooth and fluctuating exponential decay. The transfer matrix solution is used to explain these regions. The average transfer matrix is obtained exactly; where the decay is smooth its eigenvalues approximately determine the localization length.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. High-frequency asymptotics for microstructured thin elastic plates and platonics;Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences;2012-02-08
2. Ribbed elastic structures under a mean flow;Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences;2005-04-08
3. Response of irregularly ribbed elastic structures, under fluid loading, to localized excitation;Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences;1999-03-08
4. Some Analytical Methods for Fluid-Structure Interaction Problems;Fluid-Structure Interactions in Acoustics;1999