Preparation of Cu–Ni–Pt Nano-Cube and Its Application for the Detection of Nanobacteria on Influences of Flexible Ureteroscopy Lithotomy and Percutaneous Nephrolithotomy on Immune Function of Patients with Renal Calculus

Author:

Gu Xin1,Jing Liwei1,Wang Andi1,Dai Yongqiang1,Zhao Jianyong1,Shao Chunyan1

Affiliation:

1. Department of Urology Surgery, Cangzhou Hospital of Integrated Traditional Chinese and Western Medicine, Cangzhou, 061001, Hebei, China

Abstract

This work aimed to find a surgical method suitable for the clinical treatment of renal calculus, and to find a new type of nanomaterial suitable for the detection of nanobacteria. In this paper, Cu–Ni–Pt nano cube was preparation, then the combination of peptidoglycan and Pt–Ni–Cu–NCs was verified. Through continuous surface treatment and continuous modification, an electrochemical biosensor for detecting the content of nanobacteria in the body of renal calculus patients was successfully constructed. 85 patients with renal calculus were d Randomly divided into two groups, percutaneous nephrolithotomy group (PCNL group, 43 patients) and ureteroscope lithotomy (URL group, 42 patients). The venous blood was collected to test tumor necrosis factorα (TNF-α), C-reactive protein (CRP), interleukin-6 (IL-6), and IL-8 levels. Flow cytometry was employed to detect CD4+ and CD8+ T lymphocyte levels. A biosensor for the detection of nanobacteria was constructed based on peptidoglycan and Cu–Ni–Pt nano cubes (Pt–Ni–Cu–NCs), and applied to the detection of nanobacteria in the blood and urine of patients after surgery. It was found that the detection range of the constructed nanobacteria detection sensor was 1.3×102~1.5×108 CFU/mL, which had a good linear relationship. Moreover, within 30 minutes, the detection of nanobacteria in blood and urine was achieved, and a broad-spectrum detection was achieved. In contrast to PCNL group, CRP, TNF-α, IL-6, IL-8, and CD8+ were significantly lower in the URL group (P < 0.05). The detection rates of nanobacteria in blood and urine in PCNL group were 10% and 11.2%, respectively; those of URL group were 6.8% and 5.9%, respectively. Detected by the biosensor, the nanobacteria content was lower after URL treatment, and the immune function was at a higher level, which was more conducive to postoperative recovery.

Publisher

American Scientific Publishers

Subject

General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3