Bond Integrity of Titanium Surface to Resin Cement After Conditioning with Different Photobiomodulataion Therapy (PBT)

Author:

Al Ahdal Khold1,Al Deeb Laila1,Bin-Shuwaish Mohammed S.2,Al-Hamdan Rana S.2,Al Deeb Modhi3,Maawadh Ahmed M.2,Alhenaki Aasem M.3,AlHelal Abdulaziz4,Alresayes Saad3,Al-Aali Khulud A.5,Vohra Fahim4,Abduljabbar Tariq4

Affiliation:

1. Department of Restorative Dentistry, College of Dentistry King Saud University Riyadh, 60169, Saudi Arabia

2. Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia

3. Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia

4. Department of Prosthetic Dental Sciences, College of Dentistry, Research Chair for Biological Research in Oral Health, King Saud University, Riyadh 11545, Saudi Arabia

5. Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, 11671, Saudi Arabia

Abstract

The aim of the present study was to evaluate the efficacy of interfacial bonding between resin cement and titanium alloy conditioned with different Photobiomodulataion Therapy (PBT) in comparison with conventional regimes. Seventy-five samples of titanium bar were segmented polished; and based on conditioning regime divided into five groups (15 each specimens). Group 1: No treatment (control), Group 2: Sand blasting with 120 µm Al2O3, Group 3: Er,Cr:YSGG (ECL), Group 4: Er:YAG laser (EYL), Group 5: Nd:YAG laser (NYL). After different conditioning regimes, resin cement was mixed and applied. All specimens were thermocycled for 500 cycles and positioned on universal testing machine for shear bond strength testing. Modes of failure was assessed by a single examiner using stereomicroscope at 40× magnification. Three pairs of specimens in each group were sputter coated and scanning electron microscope (SEM) images were taken at 1000× magnification using 20 Kv. The highest SBS values were observed in group 2 (14.25±2.29 MPa) and the lowest bond values were displayed in group 1 (6.98 ±0.59 MPa). Titanium alloy abutments conditioned with different laser prototypes ECL (11.22±1.40 MPa), EYL (9.29±1.22 MPa) and NYL (9.12 ±1.84 MPa) exhibited comparable SBS (p > 0.05). Adhesive failures were primarily dominant among all experimental groups. Photo-biomodulation in the form of ECL lasers has the potential to be used as a supplement to sandblasting procedure in conditioning of cement retained titanium alloy implant abutments.

Publisher

American Scientific Publishers

Subject

Biomedical Engineering,Medicine (miscellaneous),Bioengineering,Biotechnology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3