Effect of Noise Adaptive Wavelet Filter on Diagnostic Performance in Stroke Perfusion

Author:

Inal Tolga1,Kaan Atac Gokce2,Telatar Ziya1

Affiliation:

1. Department of Electrical-Electronics Engineering, Ankara University, Ankara, 06830, Turkey

2. School of Medicine, Department of Radiology, Ufuk University, Ankara, 06520, Turkey

Abstract

Background: Computed tomography perfusion (CTP) images include more noise than routine clinic computed tomography (CT) images. Singular value decomposition based deconvolution algorithms are widely used for obtaining several functional perfusion maps. Recently block circulant singular value decomposition algorithms become popular for its superior property of immunity to contrast bolus lag. It is well known from literature that these algorithms are very sensitive to noise. There are a lot of examples of noise reduction filters in the literature as well as commercial ones. Functional maps which help physicians in the diagnostic process can be obtained with better image quality by de-noising CTP images with adaptive noise reduction filters. Objective: In this study, the effect of a noise adaptive wavelet filtering method on diagnostic performance on CTP stroke patient images is investigated. Method: Images of acute stroke patients were de-noised by this method and their diagnostic value were evaluated by visual means, peak signal-to-noise ratio and time intensity profile metrics. An observer evaluation study was carried out in order to validate quantitative image quality metrics. The results are compared with Gaussian and a bilateral filter based filtering method called TIPS (Time Intensity Profile Similarity) on same images sets to benchmark proposed method. Results: The diagnostic value of the images obtained from noise adaptive wavelet filtering method were better than Gaussian filter method and were compatible with a wellknown time intensity profile similarity bilateral filter method. Diagnostic performance of the both observers were improved compared to both Gaussian and TIPS methods. Conclusion: The noise adaptive wavelet filter method succeeded to reduce noise while preserving details contained in the contrast bolus. Its final effect on the timeintensity profiles and generated perfusion maps are compatible with the literature and showed improvements on diagnostic performance on specificity and overall accuracy when compared to other methods.

Publisher

American Scientific Publishers

Subject

Health Informatics,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3