Synchronous Signal Transmission Method of Minimally Invasive Renal Failure Surgery Based on Nano Molecular Image Probe

Author:

Zheng Fu1,Tian Dan1,Chen Dan2,Yao Nana2,Chen Hongbo1,Hu Xiaohui1,Lan Yong1,Chen Su1

Affiliation:

1. Department of Urology, The Central Hospital of Enshi Tujia and Miao Autonomous Prefectrue, Enshi, Hubei, 445000, China

2. Department of Anesthesiology, The Central Hospital of Enshi Tujia and Miao Autonomous Prefectrue, Enshi, Hubei, 445000, China

Abstract

The synchronous signal transmission can promote the successful completion of minimally invasive renal failure surgery, so the synchronous signal transmission method of minimally invasive renal failure surgery based on nano molecular image probe is studied. The nanoprobe is constructed by loading different signal molecules, photosensitizers, acoustic sensitizers and thermosensitives through the method of double emulsion or film hydration; the near-infrared confocal endoscope molecular image diagnosis and treatment equipment is designed based on the nanoprobe, and the intraoperative highfrequency image is obtained through the diagnosis and treatment equipment; the high-frequency injection energy and signal synchronous transmission method is adopted, and the signal is added to the primary and secondary resonance circuit. In the coupling module, a higher frequency alternating signal is added into the resonant coupling voltage to modulate the signal into the transmission resonance system, which is transmitted from the energy transmission coupling coil to the secondary end, and the injected signal part of the coupling coil is demodulated at the other end to complete the transmission of the signal coupling transmission loop, so as to realize the high-frequency image energy and index data signal of minimally invasive renal failure surgery. The experimental results show that the designed nano molecular image probe has good stability, and the simulated signal transmission waveform is consistent with the transmission waveform of the principle analysis. Applying the proposed method to the minimally invasive surgery of renal failure, it is found that the success rate and image signal transmission efficiency of the minimally invasive surgery of patients 1–5 are higher than 99.5%, and the operation image transmission accuracy is high and the operation effect is excellent.

Publisher

American Scientific Publishers

Subject

Pharmaceutical Science,General Materials Science,Biomedical Engineering,Medicine (miscellaneous),Bioengineering

Reference34 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3