Safety of Polymer Clips in Laparoscopic Living Donor Nephrectomy: Indonesian Experience

Author:

Sidabutar Karina Evelyn1,Hamid A. R1,Rasyid Nur1,Rodjani Arry1,Wahyudi Irfan1,Mochtar Chaidir A1

Affiliation:

1. Department of Urology, Faculty of Medicine, University of Indonesia – Cipto Mangunkusumo Hospital, Indonesia

Abstract

To assess the reliability and safety of polymer clips for vascular control in laparoscopic living donor nephrectomy. We collected data retrospectively from all laparoscopic living donor nephrectomy performed in Ciptomangunkusumo Hospital, Jakarta, Indonesia. Polymer clips was applied for both renal artery and renal vein ligation. The incidence of polymer clip failure was recorded accordingly. Between November 2011 and August 2015, we evaluated 260 patients of laparoscopic living donor nephrectomy in a center. The left kidney was harvested from 219 (84.5%) patients. Multiple renal arteries was discovered in 25 (9.6%) patients. For all cases we used polymer clips to control the renal artery (XL and L) and renal vein (XL). We placed 2 clips as proximal as possible to the aorta or caval vein. The median estimated blood loss was 100 (20–2000) ml. A blood loss of 2000 ml occurred in one/case of clip dislodgement. The median time to clip (the length of time from first incision to renal artery clamping) was 155 (68–318) minutes. The median warm ischemic time (the length of time from clamping to cold ischemic time) was 3.01 (1.22–30.43) minutes. There were 10 cases with warm ischemic time of more than 10 minutes. Three cases (1.2%) of clip failures occurred. One patient needed conversion to open surgery to achieve adequate vascular control. Two patients experienced improper locking of the polymer clips, necessitating clips reapplication. The use of polymer clips for vascular control in laparoscopic living donor nephrectomy is reliable and safe when properly applied. However the evaluation of renal vascular stump after harvesting donor kidney is an important step to ensure the right placement and safety of polymer clips.

Publisher

American Scientific Publishers

Subject

General Energy,General Engineering,General Environmental Science,Education,General Mathematics,Health(social science),General Computer Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3