Affiliation:
1. Peoples’ Friendship University of Russia” (RUDN University), Medical Institute
Abstract
People are increasingly paying attention to their smile and occlusion. That led to the emergence of new adhesive materials, including domestic ones. The purpose of this study is to define the indicators of detachment of brackets from three companies during clinical observation within one year after their fixation using the domestic set “Compofix (ortho)”. The study included 30 patients who had brackets fixed on both jaws on 24 teeth (from the first molar of one segment to the first molar of the opposite segment). The patients were divided into three groups: Group I included 10 patients who were fixed with brackets from Equilibrium (Dentaurum, Germany). Group II included patients who were fixed with G&H Orthodontics brackets (G&H Wire Company, USA). Group III included patients with Hangzhou brackets (JET Medical Equipment Co., Ltd China, China). Fixation in all groups was performed according to one adhesive protocol using the “Compofix (ortho)” orthodontic kit (Vladmiva, Russian Federation). The indicators were distributed as follows: Group I (12.5%) Group II (5.83%) Group III (28.75%). The study showed that G&H Orthodontics brackets (G&H Wire Company, USA) showed the best fixation to tooth enamel. Hangzhou brackets (China) showed the worst indicators of fixation to tooth enamel. The domestic complex “Compofix (ortho)” showed positive clinical indicators of fixation.
Publisher
Stomatology for All - International Dental Review
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献