Тhe effect of cancer patients’ positioning accuracy during radiation therapy sessions using medical linear electron accelerators on the parameters of their individual 3D dose distribution

Author:

Piatkevich M. N.1,Titovich E. V.2,Belkov G. V.1

Affiliation:

1. International Sakharov Environmental Institute of Belarusian State University

2. Unitary Enterprise “ADANI”

Abstract

Due to the rapid development and further improvement of radiation treatment technologies oncologists have an opportunity to precisely deliver individual dose distributions to the tumor, minimizing the doses obtained by critical organs and healthy structures. For the correct and successful application of these complex methods of radiation therapy, it was necessary to enforce the requirements for the technical and dosimetric parameters of the radiotherapy equipment. The purpose of the research is to determine the magnitude of the possible error for patients’ positioning during their radiotherapy treatments using medical linear accelerators by modeling the impact of the patient’s body on the treatment couch. To determine the values of a possible error, the authors have considered the design and characteristics of a typical treatment couch, developed a model of the “average” patient’s body (phantom), which allowed changing the load to the treatment couch with a step of 1 kg. The position parameters of treatment couches were determined for the main types of localization of radiation therapy for malignant tumors: head and neck tumors, breast tumors and pelvic tumors. Numerical values of the treatment coach deviations from prescribed horizontal position were experimentally established for a load from 40 to 180 kg for a treatment couch used at the N.N. Alexandrov National Cancer Centre of Belarus. Based on the obtained experimental data, the necessity to correct the patient's treatment conditions at the stage of treatment planning were confirmed in order to ensure the delivery accuracy of individual dose distributions as required by the radiation therapy protocols. Authors stated that an analysis of the dependence of the deviations in the dose delivered to the patients on the deviation of the radiotherapy table from its horizontal position should be carried out for each radiotherapy table used in clinical practice. The development and implementation of a mechanism that will allow considering this information when choosing the parameters of the patient’s treatment session and prescribing the dose for any localization of malignant neoplasms is needed.

Publisher

Belarusian State University of Informatics and Radioelectronics

Reference6 articles.

1. Oceanov A.I. Moiseeva P.I., Levina L.F., Evmenenko A.A., Ipatiy T.B., Sukonko O.G. [Cancer in Belarus: figures and facts. Analysis of the data of the Belarusian Cancer Register for 2009–2018]. Minsk: National Library of Belarus; 2019. (In Russ.)

2. Klimanov V.A. [Radiobiological and dosimetric planning of radiation and radionuclide therapy. P. 1. Radiobiological basis of radiation therapy. Radiobiological and dosimetric planning of remote radiation therapy with braking and gamma radiation beams]. Moscow: NRNU MEPhI; 2011. (In Russ.)

3. Tepper J., Foote R., Michalski J. Clinical radiation oncology. 5th Ed. Elsevier; 2020.

4. Tarutin. I.G. [The use of linear electron accelerators in high-tech radiation therapy]. Minsk: Belaruskaya Navuka; 2015. (In Russ.)

5. Practical issues in treating heavy patients on a LINAC treatment couch. Journal of applied clinical medical physics. 2005;6(1):45-56.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3