Accuracy of Prenatal Ultrasonography for Diagnosis of Placenta Accreta Spectrum and Risk Factors in A Tertiary Center in Southern Iran

Author:

Vafaei Homeira,Hadipour Neda,Kasraeian Maryam,Yoosefi Sedigeh,Moradi Alamdarloo Shaghayegh,Asadi Nasrin,Oveisi Zahra,Bahari Hossein,Zare Marjan,Bazrafshan Khadije

Abstract

Background: Placenta accreta spectrum is one of the most important causes of massive bleeding in the peripartum period. The aim of this study was to determine the accuracy of prenatal ultrasonography for diagnosis of placenta accreta spectrum (PAS) and important risk factors of this pathology were evaluated in this report. Materials and Methods: This is a cross-sectional study conducted at Shiraz University of Medical Sciences during January 2018 to January 2019. All patients who were referred for ultrasound examination of placenta accrete spectrum and surgery in Hafez tertiary center were included. Patients with diagnosis of PAS in pathology were in one group and the others in the second group. All maternal and neonatal and demographic data and surgery complications were gathered in a data form. Results: Ultrasonography was 100% (95% C.I: 94.40%-100%) sensitive, 87.58% (95% C.I; 81.29%-92.36) specific, and 87.58% (95% C.I: 82.44%-91.66%) accurate discriminating PAS from non-PAS patients. From 217 patients, 64 and 153 patients were in PAS and non-PAS group, respectively. There was significantly more age, gravidity, live children, history of D&C, hormonal contraception, and history of previa in PAS group compared with Non-PAS group (p-value<0.05 for all); however, gestational age was significantly lower in PAS group (p-value<0.05). The odds of PAS significantly increase with previa and low-lying placenta OR adj (95% C.I): 114.68 (28.45-462.29). The patients with one C/S OR adj (95% C.I): 29.07(3.80-222.33) and the patients with two C/S OR adj (95% C.I): 106.08(13.79-815.51) were significantly more in PAS group compared with those with no C/S (p-value <0.05 for both). Conclusion: Detection rate of ultrasound examination was good, and it is recommended for women with PAS risk factors. Decreasing the rate of cesarean section and encouraging vaginal birth after cesarean section (VBAC) are the best ways of prevention of this pathology.

Publisher

Salvia Medical Sciences Ltd

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3