Performance of Isolated Footing with Several Corrosion Levels under Axial Loading

Author:

Youssef AhmedORCID,Hegazy Mahmoud,Mostafa Hatem

Abstract

This research aims to illustrate the corrosion process and its effect on the deterioration of reinforced concrete (RC) isolated footings using a small-scale model (1/8) and present the results of a prototype-scale study using a numerical model with different concrete depths and corrosion levels under axial load. The experimental program consisted of testing five small-scale (1/8) model RC isolated footings under axial loading after subjecting them to accelerated corrosion tests with a constant current. The main variable in the small-scale sample test was the corrosion level. This study presents an experimental approach, using the constant current method and the finite element method (FEM) with the ABAQUS package, to examine its effect on the axial load behavior under different corrosion ratios, which were 0%, 4.21%, 9.11%, 24.56%, and 30.67%. On the prototype scale, the variables were the corrosion level and the RC depths of 300 mm, 400 mm, and 500 mm. The results indicated that the average deviation in ultimate load between the experimental and FEM outcomes for the small-scale was below 5.6%, while the average deflection deviation was 6.8%. Also, the study found that an increase in the depth of the RC footing and corrosion ratio led to a more pronounced impact of the cracking pattern in the concrete and corroded bars, as well as a greater difference in the failure load. The experimental results suggest that the proposed numerical model is accurate and effective. These findings have important implications for the evaluation of isolated footings affected by corrosion damage using FEM, and can help inform decisions related to their design and maintenance. The failure loads of non-corroded footings with different depths were compared with the ECP-203 provisions of the 2018 Egyptian Code, and how corrosion ratios can be simulated by numerical models. The percentage variation between the design loads by code and the numerical loads by ABAQUS for controlled footings with thicknesses of 300, 400, and 500 mm was found to be 73%, 80%, and 78%, respectively. Using the derived relationship, the equivalent corrosion ratio percentages were 23.8%, 20.2%, and 32%, respectively. Doi: 10.28991/CEJ-2023-09-06-011 Full Text: PDF

Publisher

Ital Publication

Subject

Geotechnical Engineering and Engineering Geology,Building and Construction,Civil and Structural Engineering,Environmental Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3