Abstract
Due to the high cost and less availability of land, the buildings are constructed adjacent to each other with a significantly smaller separation gap. Whenever seismic forces act on adjacent structures, they collide and cause significant structural and architectural damage. Soil-Structure Interaction (SSI) effects cause more complications in the adjacent structures. This paper assesses the gap distance between RC bare frame adjacent structures of varying heights in medium and soft soil with and without SSI to avoid the pounding effect of an earthquake. The main objectives are to find the separation distance between adjacent buildings by the provisions of FEMA 356, IS 1893 (Part 1):2002, IS 1893 (Part 1):2016 and EN 1998-1:2004. The separation gap between different codes was then compared to determine the minimum separation required to prevent pounding between the structures. The maximum lateral displacement on the roof and the time period of the adjacent buildings are compared with and without SSI. There is a significant increase in lateral displacement, separation distance, and time period considering SSI. It is found that the Indian code overestimates the separation distance. Thus, this study guides structural engineers to maintain a minimum separation distance between buildings erected on medium and soft soils in high seismic zones of India. Doi: 10.28991/CEJ-2022-08-02-09 Full Text: PDF
Subject
Geotechnical Engineering and Engineering Geology,Building and Construction,Civil and Structural Engineering,Environmental Engineering
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献