Fire Resistance Analysis of Two-Way Reinforced Concrete Slabs

Author:

Salihu Fidan,Guri Zijadin,Cvetkovska Meri,Pllana Fatos

Abstract

This paper presents a fire resistance analysis of two-way reinforced concrete (RC) slabs. The study analyzes the effect of specific parameters—concrete cover thickness, span, and support conditions—on the fire resistance of the slabs. To that end, the slabs were exposed to Standard Fire ISO 834, and the 3D nonlinear numerical analyses were conducted in SAFIR2016. The results of the numerical analyses were evaluated against experimental results reported in the literature. The agreement between the two sets of results was satisfactory throughout the fire test. Nonetheless, to verify the obtained numerical results, all testing-related parameters must comply with the numerical simulation results. This comparison demonstrated the usefulness of numerical simulations in predicting the behavior of structures in fire conditions. In addition to the nonlinear numerical analysis, the fire resistance was calculated using the simplified method and tabulated data described in Eurocode 2 (Part 1.2) to assess the accuracy and reliability of fire safety regulations in the design of two-way slabs and identify significant differences between the design code and numerical analysis. The comparison showed that SAFIR2016 provides more accurate results by considering additional factors, such as tensile membrane forces, which increase the fire resistance of two-way slabs. According to the load-bearing criteria, the two-way slabs have high fire resistance, considerably higher than prescribed in the fire safety regulations, which ignore the positive effect of tensile membrane forces. According to the numerical analysis, the upper reinforcement in the compression areas of the slab's span was considered, which increased the fire resistance of the slabs. In contrast, according to the design codes, the contribution of this reinforcement is neglected. It was indicated that the increased concrete cover improves the fire resistance of the slabs. The vertical displacements increase by increasing the slab span, but according to the load-bearing criteria, all the slabs show fire resistance of over ten hours. In terms of bearing capacity, slabs with various support conditions show fire resistance of longer than ten hours. In terms of deflections, the supporting conditions of the slabs have a significant influence on their behavior. This study provides valuable insights into the fire resistance of two-way RC slabs and highlights the importance of considering specific parameters in the analysis. Doi: 10.28991/CEJ-2023-09-05-05 Full Text: PDF

Publisher

Ital Publication

Subject

Geotechnical Engineering and Engineering Geology,Building and Construction,Civil and Structural Engineering,Environmental Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3