A comparative study of different contrast administration routes efficiency performed on in vivo colorectal cancer models

Author:

Goncharova A. S.1ORCID,Khodakova D. V.1ORCID,Galina A. V.1ORCID,Zaikina A. V.1ORCID,Kurbanova L. Z.1ORCID,Mindar M. V.1ORCID,Gurova S. V.1ORCID

Affiliation:

1. National Medical Research Centre for Oncology

Abstract

Purpose of the study. The investigation is aimed to provide a systematic comparison of different contrasting methods for in vivo micro-CT diagnostic of orthotopic colorectal cancer models extracted by ortotopic implantation into the caecum of immunocompromised mice BALB/c Nude lines.Materials and methods. BALB/c Nude (N = 25) female mice were implanted by transplanted human colorectal cancer strain into the cecum. 20 days after the implantation mice were administered with iodine-based contrast agent Optiray by means of different administration method (intravenously, per os, intraperitoneally, per rectum) and micro-CT scans have been registered via Quantum GX2 tomograph. Measurement of tumor nodes was performed both by means of estimation from micro-CT images via RadiAnt DICOM Viewer software and by means of explicit measurements using calipers upon laparotomy and posthumously. At the last stage of the study, the animals were euthanized by cervical dislocation. The tumors were excised, measured with a caliper and placed in 10 % formalin for the standard histological analysis according to the standard methods.Results. The average volumes of tumor xenografts in animals with intravenous, oral, and intraperitoneal contrast administration measured at micro-CT were 53.7 ± 5.2 mm3, 52.7 ± 6.4 mm3 and 63.6 ± 5.6 mm3 respectively; measured at laparotomy – 43.0 ± 5.5 mm3, 44.5 ± 5.4 mm3 and 58.5 ± 5.5 mm3 respectively; measured post-mortem – 55.2 ± 6.6 mm3, 53.2 ± 8.8 mm3 and 65.9 ± 3.8 mm3 respectively. The average volumes of tumor xenografts isolated post-mortem in these groups were comparable with the values shown at micro-CT, but larger than the volumes measured at laparotomy.Conclusion. The results obtained demonstrated that intravenous, peroral and intraperitoneal administration techniques provide the best visualization of laboratory rodents pathological tissue upon in vivo micro-CT diagnostics and thus are preferred.

Publisher

QUASAR, LLC

Subject

Microbiology (medical),Immunology,Immunology and Allergy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3