Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

Author:

Yu Young SamORCID,Kim Jinsol,Park Chan,Jeong Woong-Seob,Kim Minjin,Choi Seonghwan,Park Sung-Joon

Abstract

The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny–Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200–9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain (2.86 e−/ADU), full well capacity (130 K e−), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is 12 e−. The dark current at 223 K was determined to be 7 e−/s/pix and its doubling temperature is 5.3°C ± 0.2°C at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be 93 % ± 2 %. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.

Publisher

The Korean Space Science Society

Reference19 articles.

1. Andor Technology , iKon-M 934 Series Specification (2008).

2. Braunstein R , Moore A, Hermann F, Intrinsic optical absorp-tion in germanium-silicon alloys, Phys. Rev. 109, 695-710 (1958). https://doi.org/10.1103/PhysRev.109.6950031-899X

3. Fossum E , Active pixel sensors: are CCDs dainosaurs?, Proc. SPIE 1900, 2-14 (1993). https://doi.org/10.1117/12.1485850277-786X

4. Holland SE , Fully depleted charge-coupled devices, in the International Symposium on Detector Development for Particle, Astrophysics, and Synchrotron Radiation Experiments (SNIC06), Stanford Linear Accelerator Center, Menlo Park, CA, 3-6 Apr 2006.

5. Janesick JR , Photon Transfer DN → λ (SPIE press, Bellingham, 2007).

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Research on a back-illuminated CMOS sensor for LUV imaging;Journal of Instrumentation;2022-08-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3