Abstract
Introduction: Fire cases increase in residential buildings because short circuits, at dormitories are mostly affected by human factors. X university dormitory building is a place for 24 hours of students’ activities with a lot of electricity consumption, bad behavior; overpowering extensions, and many flammable objects such as paper and furniture. Research objectives are to investigate the appropriateness and mapping needs of fire protection systems with regulations. Methods: The research is a semi quantitative analysis. Primary data is conducted with observations by using a checklist form that refers to the regulations and results of managers' interviews. The obtained data are categorized into good with suitability >79-100%, moderate ≥60%-79% and poor <60%. Result: The appropriateness of the active fire protection system is under 60% or in the poor category. The appropriateness of the fire extinguisher is 47.77%, the hydrant is 58.75%, the alarm is 18.75% and the heat detector is 35.90%. There is no sprinkler installation in the dormitory building and no commitment from the top management regarding occupational safety and health. Fire extinguisher’s need is 10 tubes per floor, the number of hydrants have been fulfilled, alarm requires an additional 1 unit on each floor and a heat detector requires a total of 114 units. Conclusion: The active fire protection system is still under 60% (poor category) and no maintenances. Based on the aforementioned mapping results, it needs to add the number of piece equipment according to the regulations and maintenance efforts.Keywords: active fire protection system, dormitory, mapping
Reference23 articles.
1. Badan Standar Nasional Indonesia (2000a) SNI-03- 3985-2000 Tata Cara Perencanaan, Pemasangan dan Pengujian Sistem Deteksi dan Alarm Kebakaran untuk Pencegahan Bahaya Kebakaran pada Bangunan Gedung. Jakarta: Badan Standar Nasional Indonesia.
2. Badan Standar Nasional Indonesia (2000b) SNI 03-1745-2000 Tentang Tata Cara Perencanaan dan Pemasangan Pipa Tegak dan Slang untuk Pencegahan Bahaya Kebakaran pada Bangunan Rumah dan Gedung. Jakarta: Badan Standar Nasional Indonesia.
3. Analysis of the Active and Passive Fire Protection Systems in the Government Building, Depok City, Indonesia;Djunaidi;KnE Life Sciences,2018
4. Smartfire: Intelligent Platform for Monitoring Fire Extinguishers and Their Building Environment;Garcia-Martin;Sensors,2019
5. Government Regulation of the Republic of Indonesia (2005) Nomor 36 Tahun 2005 Tentang Pelaksanaan Undang-Undang No.28 Tahun 2002 Tentang Bangunan Gedung. Jakarta: President of the Republic of Indonesia.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Perencanaan Fire Alarm dan Pemadam Kebakaran pada Gedung Dekanat 7 Lantai Universitas Tidar Mertoyudan;Aviation Electronics, Information Technology, Telecommunications, Electricals, and Controls (AVITEC);2024-08-01