Author:
Alhamdani Faaiz,Rasheed Khawla H.,Mahdi Amjed
Abstract
Background: The introduction of modified thread designs is one of the research areas of interest in the dental implantology field. Two suggested Buttress and Reverse Buttress thread designs in TiG5 and TiG4 models are tested against a standard TiG5 Fin Thread design (IBS®). Purpose: The study aims to compare stress distribution around the suggested designs and Fin Thread design. Methods: Three dental implant models: Fin Thread design, and newly suggested Buttress and Reverse Buttress designs of both TiG5 and TiG4 models were tested using FEA for stress distribution using static (70N, 0°) and (400N, 30°) occlusal loads. Results: The main difference between the suggested Buttress design and Fin Thread design lies in the overload (400N, 30°) condition. Maximum Von Mises stress is less in Buttress design than Fin Thread design. On the other hand the level of Von Mises stress over the buccolingual slop of the cancellous bone in Fin Thread design liess within the lowest stress level. The suggested Reverse Buttress design, on the other hand showed almost uniform stress distribution in both TiG4 and TiG4 models with maximum Von Mises stress higher than the elastic modulus of cancellous bone in overload (400N, 30°) condition. Conclusion: The suggested TiG4 Buttress design might have a minor advantage of stress level in cases of stress overload. In contrast, Fin Thread design shows minimal stress over the buccolingual slop of the cancellous bone. The suggested Reverse Buttress design might be more suitable for the D1 bone quality region with the advantage of almost uniform stress distribution
Reference37 articles.
1. Bicudoa P, J.Reisb, Deusc AM, et al. Mechanical behaviour of dental implants. Procedia Structural Integrity 2016: 026-033.
2. Soliman TA, Tamam RA, Yousief SA, et al. Assessment of stress distribution around implant fixture with three different crown materials. Tanta Dental Journal 2015: 249-258.
3. Dental Implant Thread Design and the Consequences on Long-Term Marginal Bone Loss;Ormianer;Implant Dent,2016
4. Zarei I, Khajehpour S, Sabouri A, et al. Assessing the Effect of Dental Implants Thread Design on Distribution of Stress in Impact Loadings Using Three Dimensional Finite Element Method. Journal of dental biomaterials 2016; 3: 233-240.
5. Finite element analysis of stress distribution around a dental implant with different amounts of bone loss: An in vitro study;Jafarian;Dent Med Probl,2019