Affiliation:
1. Beykent University, Istanbul
2. Turkish Naval Academy, Istanbul
Abstract
Decreasing industrial energy sources and major environmental problems caused by uncontrolled energy consumption have led to studies on alternative energy sources. This study presents a design and experimental analysis of an exhaust gas-driven absorption refrigeration system for the purpose of air conditioning by using the exhaust heat of a diesel engine, which is installed in the Naval Academy Mechanics Laboratory. The diesel engine is loaded with a dynamometer, and water and ammonia are used as an absorbent and refrigerant, respectively. At various diesel engine loads, cooling capacity and coefficient of performance (COP) of the absorption refrigeration system are calculated. Experimental results have indicated the cooling capacity as 1.098 kW at a maximum engine power of 4.9 HP. The highest COP value in the designed system has been calculated to be .3022 for the generator temperature of 160 C. Although the COP of refrigeration is low, the absorption refrigeration system can be provided a great cooling load from the exhaust heat of diesel engines and can be used in naval surface ships. In addition to energy efficiency of naval surface ships, infrared and acoustic signature can be minimized and a ships susceptibility can be dramatically reduced.
Publisher
The Society of Naval Architects and Marine Engineers
Subject
Mechanical Engineering,Ocean Engineering
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献