Abstract

Background: Indoor air quality is associated with the etiopathogenesis of many diseases. This condition also produces many medical symptoms. The purpose of the current study is to measure indoor air quality parameters in a medical faculty hospital and to determine the medical complaints of hospital staff and patients/patient relatives related to the indoor air quality. Methods: This cross-sectional, descriptive research was conducted with 442 participants between February 28 and March 22, 2021. For the indoor air quality in the hospital; temperature, relative humidity, air flow rate, light level, nitrogen oxide (NO), hydrogen sulfide (H2S), sulfur dioxide (SO2), carbon monoxide (CO), carbon dioxide (CO2) gas levels were evaluated according to the standards. The association between socio-demographic characteristics, medical complaints and indoor air quality were analyzed in hospital staff and patients/patient relatives. Results: It was determined that 80.3% of the air temperature and 22.7% of the relative humidity measurements in the study were in the standard limits and almost all of the air flow velocity and 81.0% of the illumination level measurements were not in standard limits. It was determined that particulate matter level was measured normal levels according to International Organization for Standardization (ISO) 5 class in the all-environmental area. NO, H2S and SO2 were detected in the hospital with indoor gas measurements. CO gas was detected in a small part of the hospital. The majority of CO2 measurements were in line with standards. The most common symptoms of the participants associated with indoor air of the hospital were fatigue, dyspnea, and dysesthesia. Conclusion: While most of the hospital indoor temperature measurements were in accordance with the standards, most of the humidity, airflow velocity and lighting measurements were not in accordance with the standards. NO, H2S, SO2 gases were not detected in the hospital, while CO was detected in 2 areas.

Funder

The research was funded by the Scientific Research Projects Unit of Necmettin Erbakan University

Publisher

Selcuk University

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3