Virtual Touch Quantification using Acoustic Radiation Force Impulse Imaging Technology versus Transient Elastography for the Noninvasive Assessment of Liver Fibrosis in Patients with Chronic Hepatitis B or C using Liver Biopsy as the Gold Standard

Author:

Bâldea Victor,Sporea Ioan,Tudor Anca,Popescu Alina,Bende Felix,Șirli Roxana

Abstract

Aims: Our aim was to assess the diagnostic performance of transient elastography (TE) and Virtual Touch Quantification (VTQ), a point Shear Wave Elastography (pSWE) technique, using Acoustic Radiation Force Impulse (ARFI) technology, for liver fibrosis assessment, as compared to percutaneous liver biopsy (LB), in patients with chronic hepatitis B or C. Methods: We analyzed 157 patients (80 with chronic hepatitis B and 77 with chronic hepatitis C) with reliable liver stiffness (LS) measurements, in whom we compared TE and VTQ to the LB performed during the same session (evaluated according to the Metavir scoring system: F0-F4). LS was assessed by TE (FibroScan, EchoSens, Paris, France) and VTQ using the Siemens Acuson S2000TM ultrasound system (Siemens AG, Erlangen, Germany). We defined reliable LS measurements as the median value of 10 measurements with an IQR/M <30% for both TE (obtained using the M probe) and VTQ. The areas under receiver operating characteristic curves (AUROCs) were used to assess the diagnostic performance of TE and VTQ. Correlation analysis determined the relationship between LSM values and liver histology. Results: On LB 31 (19.7%) patients had no fibrosis, 35 (22.3%) had F1, 43 (27.4%) had F2, 28 (17.8%) had F3 and 20 (12.7%) had cirrhosis. The mean size of the liver specimen in LB was 27 mm. A strong, linear correlation (Spearman ρ=0.826; p<0.001) with 95% confidence interval for rho (0.769- 0.870), was found between the TE and VTQ measurements. By comparing the AUROC curves, TE and VTQ had similar predictive values for the presence of F≥1 Metavir: AUROC TE=0.876, AUROC VTQ=0.832, p=0.358, for F≥2 Metavir: AUROC TE=0.826, AUROC VTQ=0.862, p=0.313, for F≥3 Metavir: AUROC TE=0.907, AUROC VTQ=0.880, p=0.434 and for F=4 Metavir: AUROC TE=0.981, AUROC VTQ=0.974, p= 0.423. Conclusions: Both methods, TE and VTQ (pSWE) offer excellent diagnostic accuracy for liver fibrosis assessment in patients with chronic hepatitis B or C with similar performance.

Publisher

Romanian Society of Gastroenterology and Hepatology

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3